SBS Parapet (Typical)

Jump to: navigation, search

SBS Parapet (Typical)

Revision as of 14:44, 19 July 2016 by James Klassen (talk | contribs) (RELATED WORK BY OTHERS)

10.3.1.1.jpg

1 WORK INCLUDED

1. Gypsum Board
If required by design authority.
2. Vapour Retarder
If required by design authority.
3. Insulation
See list of Accepted Materials.
4. Insulation Overlay Board
As required.
5. Primary Membrane and Membrane Protection
6. Membrane Flashing
Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge.
7. Metal Base Flashing
Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
8. Metal Cap Flashing
Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams.

2 RELATED WORK BY OTHERS

(A) Acceptable Steel Deck
(B) Air / Vapour Seal
(C) Acceptable Wall Surface
(D) Wood Blocking
(E) Sloped Wood Blocking: Required over 100 mm (4") parapet width. See RGC Guarantee Standard A6.9

NOTE: Refer to RGC Guarantee Standards for additional requirements.]