SBS Equipment Sleeper

Jump to: navigation, search

SBS Equipment Sleeper

Revision as of 18:34, 4 August 2016 by James Klassen (talk | contribs)

10.3.5.2.jpg

1 WORK INCLUDED

(1) Gypsum Overlay Board
If required by design authority.
(2) Vapour Retarder
If required by design authority.
(3) Insulation
See available insulation products in the Accepted Materials section of this Manual.
(4) Insulation Overlay Board
As required.
(5) Primary Membrane and Membrane Protection
(6) Membrane Flashing
Lap one ply from each side over top of sleeper (C) and mechanically fasten.
(7) Alternate Cap Flashing
May be used instead of lapping membrane flashing over sleeper.
(8) Metal Base Flashing
Mechanically fasten to top of wood blocking, standing seam at corners, optional on flexible membrane systems. Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
(9) Metal Cap Flashing
NOTE: (8) and (9) may be one piece.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Air / Vapour Seal
(C) Wood Blocking/Sleeper
Minimum 150 mm (6") thick, minimum 100 mm (4") above finished roof surface.


NOTE: Refer to RGC Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details