1 WORK INCLUDED
- Gypsum Board
- If required by design authority.
- Vapour Retarder
- If required by design authority.
- Insulation
- See list of Accepted Materials.
- Insulation Overlay Board
- As required.
- Primary Membrane and Membrane Protection
- Membrane Flashing
- Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge. See Perimeter Flashings: Membrane for RoofStar Guarantee Standards.
- Metal Base Flashing
- Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
- Metal Cap Flashing
- Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams. See Perimeter Metal Flashings for requirements.
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Air / Vapour Seal
(C) Acceptable Wall Surface
(D) Wood Blocking
(E) Sloped Wood Blocking: Required over 100 mm (4") parapet width. See RGC Guarantee Standard A6.9
NOTE: Refer to RGC Guarantee Standards for additional requirements.]