- 15:18, 8 April 2016 (diff | hist) . . (+6,362) . . N Template:ROOFTOP GARDENS, PLANTERS & WALKWAYS (EPDM, TPO) (Created page with "==== General ==== Thermoset (EPDM) single ply membranes used for Landscaped and Vegetated roofing systems shall be fully adhered and a minimum thickness of 1.5mm (0.060"). M...")
- 15:14, 8 April 2016 (diff | hist) . . (+13,141) . . N Template:All Systems - MEMBRANES SBS (Created page with "==== General ==== While the roof is being applied, all membrane openings at eaves, walls, vents, etc. must be sealed to prevent moisture from entering roofing or between plies...")
- 15:11, 8 April 2016 (diff | hist) . . (-6) . . Template:All Systems - MEMBRANES EPDM, TPO
- 15:08, 8 April 2016 (diff | hist) . . (+3,346) . . N Template:All Systems - MEMBRANES EPDM, TPO (Created page with "==== General ==== While the roof is being applied, all membrane openings at eaves, walls, vents, etc. must be sealed to prevent moisture from entering roofing or between plies...")
- 15:05, 8 April 2016 (diff | hist) . . (+985) . . Template:All Systems - INSULATION OVERLAY BOARD EPDM (→Using Adhesives)
- 15:00, 8 April 2016 (diff | hist) . . (+262) . . Template:All Systems - INSULATION OVERLAY BOARD EPDM (→Using Adhesives)
- 14:55, 8 April 2016 (diff | hist) . . (+28) . . Template:All Systems - INSULATION OVERLAY BOARD EPDM (→General)
- 14:54, 8 April 2016 (diff | hist) . . (+3,740) . . N Template:All Systems - INSULATION OVERLAY BOARD EPDM (Created page with "==== General ==== RGC accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, XEPS, Polyisocyanurate) on all adhered low slope roofing sy...")
- 14:50, 8 April 2016 (diff | hist) . . (+41) . . Template:All Systems - INSULATION EPDM, TPO (→Adhering Insulation)
- 14:48, 8 April 2016 (diff | hist) . . (0) . . Template:All Systems - INSULATION EPDM, TPO (→Nailing Strips)
- 14:47, 8 April 2016 (diff | hist) . . (+536) . . Template:All Systems - INSULATION EPDM, TPO (→Nailing Strips)
- 14:46, 8 April 2016 (diff | hist) . . (-8) . . Template:All systems - INSULATION (→Nailing Strips)
- 14:45, 8 April 2016 (diff | hist) . . (+122) . . Template:All Systems - INSULATION EPDM, TPO (→Mechanical Fastening)
- 14:37, 8 April 2016 (diff | hist) . . (+83) . . Template:All Systems - INSULATION EPDM, TPO (→Mechanical Fastening)
- 14:24, 8 April 2016 (diff | hist) . . (+428) . . Template:All systems - INSULATION (→Nailing Strips)
- 14:19, 8 April 2016 (diff | hist) . . (-516) . . Template:All Systems - INSULATION EPDM, TPO (→Nailing Strips)
- 14:18, 8 April 2016 (diff | hist) . . (+91) . . Template:All Systems - INSULATION EPDM, TPO (→Nailing Strips)
- 14:17, 8 April 2016 (diff | hist) . . (+15,082) . . N Template:All Systems - INSULATION EPDM, TPO (Created page with "==== General ==== Only RGC Accepted insulations, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bituminous loose laid, or...")
- 14:12, 8 April 2016 (diff | hist) . . (-424) . . Template:All systems - INSULATION (→Nailing Strips)
- 22:25, 7 April 2016 (diff | hist) . . (+5,422) . . N Template:All systems - ROOF DECKS EPDM, TPO (Created page with "<b>Concrete</b> :* Concrete decks, curbs and equipment pads must be clean, dry, and smooth prior to commencement of roofing. :* Poured concrete or lightweight concrete decks...")
- 22:08, 7 April 2016 (diff | hist) . . (+28) . . Template:All Systems - MATERIALS
- 22:05, 7 April 2016 (diff | hist) . . (+27) . . Template:All Systems - MATERIALS
- 14:46, 6 April 2016 (diff | hist) . . (-4) . . Template:All systems - INSULATION (→Mechanical Fastening)
- 18:00, 5 April 2016 (diff | hist) . . (+83) . . Template:All systems - INSULATION (→Mechanical Fastening)
- 17:50, 5 April 2016 (diff | hist) . . (-5) . . Template:All systems - INSULATION (→Nailing Strips)
- 17:39, 5 April 2016 (diff | hist) . . (-2) . . Template:All systems - ROOF DECKS
- 16:07, 5 April 2016 (diff | hist) . . (+4) . . Template:All systems - INSULATION (→Mechanical Fastening)
- 15:50, 5 April 2016 (diff | hist) . . (0) . . Template:All systems - INSULATION (→Nailing Strips)
- 15:35, 5 April 2016 (diff | hist) . . (+1) . . Template:All Systems - INSULATION OVERLAY BOARD (→Mechanical Fastening)
- 15:34, 5 April 2016 (diff | hist) . . (+31) . . Template:All Systems - INSULATION OVERLAY BOARD (→Joint Taping)
- 15:33, 5 April 2016 (diff | hist) . . (+7) . . Template:All Systems - INSULATION OVERLAY BOARD (→Using Adhesives)
- 15:33, 5 April 2016 (diff | hist) . . (-11) . . Template:All Systems - INSULATION OVERLAY BOARD (→Using Adhesives)
- 15:23, 5 April 2016 (diff | hist) . . (+208) . . Fasteners (→Wind Uplift)
- 15:19, 5 April 2016 (diff | hist) . . (+29) . . Fasteners (→Roofing Nails)
- 15:19, 5 April 2016 (diff | hist) . . (+61) . . Fasteners (→Fastener Corrosion)
- 15:18, 5 April 2016 (diff | hist) . . (+63) . . Fasteners (→Mechanical Fasteners)
- 15:12, 5 April 2016 (diff | hist) . . (+29) . . Fasteners (→Adhesives)
- 15:11, 5 April 2016 (diff | hist) . . (+31) . . Fasteners (→General)
- 15:06, 5 April 2016 (diff | hist) . . (+37) . . Insulation Joints and Overlays (→General)
- 15:52, 4 April 2016 (diff | hist) . . (+3,712) . . N Template:All Systems - INSULATION OVERLAY BOARD (Created page with "==== General ==== RGC accepted insulation overlay boards shall be installed over all plastic foam insulations (EPS, XEPS, Polyisocyanurate) on all adhered low slope roofing sy...")
- 15:48, 4 April 2016 (diff | hist) . . (-6) . . Template:All systems - INSULATION (→Polyisocyanurate Insulation)
- 15:48, 4 April 2016 (diff | hist) . . (+15,082) . . N Template:All systems - INSULATION (Created page with "==== General ==== Only RGC Accepted insulations, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bituminous loose laid, or...")
- 15:44, 4 April 2016 (diff | hist) . . (+15,082) . . N Template:All Systems - INSULATION (Created page with "==== General ==== Only RGC Accepted insulations, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bituminous loose laid, or...")
- 15:39, 4 April 2016 (diff | hist) . . (+310) . . N Template:All systems - VAPOUR RETARDERS (Created page with "<div class="principles">The decision to use, and the selection of, an air/vapour retarder is the responsibility of the design authority. Neither RGC nor the roofing contracto...")
- 15:36, 4 April 2016 (diff | hist) . . (+310) . . N Template:All Systems - VAPOUR RETARDERS (Created page with "<div class="principles">The decision to use, and the selection of, an air/vapour retarder is the responsibility of the design authority. Neither RGC nor the roofing contracto...")
- 15:07, 4 April 2016 (diff | hist) . . (+4) . . Template:All systems - ROOF DECKS
- 15:05, 4 April 2016 (diff | hist) . . (+5,800) . . N Template:All systems - ROOF DECKS (Created page with "<b>Concrete</b> :* Concrete decks, curbs and equipment pads must be clean, dry, and smooth prior to commencement of roofing. :* Poured concrete or lightweight concrete decks...")
- 20:23, 22 March 2016 (diff | hist) . . (+2) . . CS Details:E3.7.3 (Hip & Ridge Caps) (→RELATED WORK BY OTHERS)
- 20:22, 22 March 2016 (diff | hist) . . (+1,516) . . CS Details:E3.7.3 (Hip & Ridge Caps)
- 23:15, 29 January 2016 (diff | hist) . . (+107) . . Template:All Systems - MATERIALS