Search results
Search results
Create the page "A" on this wiki! See also the search results found.
- ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep3 KB (347 words) - 16:48, 23 October 2017
- ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep3 KB (332 words) - 16:49, 23 October 2017
- ...]]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. ;(A) [[RoofStar Guarantee Standards for EPDM Roof Assemblies#EPDMDECKS|'''Accep3 KB (334 words) - 18:30, 23 October 2017
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...re secured to the roof deck by means of mechanical fastening, adhesive, or a combination of both.7 KB (999 words) - 15:42, 9 September 2021
- This is the first part of a multi-part series on the Building Code and roofing: ...t is all done, the commissioned building must be safe, accessible, provide a healthy environment for people, energy efficient, and it must capably prote21 KB (3,118 words) - 16:32, 16 March 2023
- ...u> </u>than the box height with a 12.7mm (½") drip edge. Installed in a thin bed of compatible mastic. Interface between outside wall and scupper s ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure3 KB (440 words) - 18:14, 27 October 2023
- ...u> </u>than the box height with a 12.7mm (½") drip edge. Installed in a bed of compatible mastic. Interface between outside wall and scupper shoul ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure3 KB (420 words) - 18:15, 27 October 2023
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...ey are produced naturally or by industrial distillation and are usually in a solid or semi-solid state at ambient temperatures.15 KB (2,293 words) - 15:33, 9 September 2021
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan A combination of technological and economic factors has brought about the inc23 KB (3,307 words) - 15:57, 9 September 2021
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...tuminous, and built-up roof membranes. In addition, the top ply or felt in a BUR must be protected from weather exposure to prevent “wicking𔄪 KB (1,280 words) - 16:25, 9 September 2021
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...ubject to many life-shortening elements, and it must function as more than a waterproofing agent. In addition to ultraviolet degradation, thermal cyclin11 KB (1,624 words) - 16:21, 9 September 2021
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan Water-shedding materials are used on roofs that typically have a slope of 1:3 (4" in 12") or greater. Generally, the materials installed on2 KB (256 words) - 16:19, 9 September 2021
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...ange on the remaining three sides. Continuous ridge air vents must provide a minimum of 50 mm (2”) of flashing flange to overlap roofing material on e6 KB (911 words) - 15:33, 9 September 2021
- ...s is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Stan ...water to freeze and form an ice dam. As the ice dam grows bigger, it forms a barrier, which prevents water from draining. The water backs up behind the3 KB (400 words) - 15:35, 9 September 2021
- {{Special:PrefixIndex/Materials:A}}286 bytes (38 words) - 19:15, 12 October 2016
- ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[TPO Membrane Termination A | Membrane Termination A]]3 KB (435 words) - 16:39, 26 February 2024
- ...' specifications and the '''''RoofStar Guarantee Standards''''' to develop a system acceptable to both the manufacturer and the '''''RoofStar Guarantee <li>[[EPDM Membrane Termination A | Membrane Termination A]]3 KB (412 words) - 16:30, 26 February 2024
- ...adhesive. Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface. Welded or adhere ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Assemblies#TPODECKS|'''Acc4 KB (462 words) - 17:01, 23 October 2017
- ;(A) [[EPDM Roof Systems Standard#PART_2|'''Acceptable Deck''']]2 KB (281 words) - 21:53, 27 June 2022
- ;(A) [[EPDM Roof Systems Standard#PART_2|'''Acceptable Deck''']]3 KB (422 words) - 21:33, 27 June 2022