1 WORK INCLUDED

(1) Architectural Metal Roof Panel
(2) Ventilation Layer
Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Underlayment
The type of underlay required is determined by roof slope.
(4) Metal Panel Clip
Installed to metal roof panel manufacturer’s printed instructions.
(4) Architectural Metal Roof Panel
(5) Eave Protection
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
(6) Metal flashing underlayment/separation membrane
required for metal flashings installed on wood substrates.
(7) Edge Metal Flashing (Continuous)
(8) Continuous metal cleat

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Fascia Board

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.