The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.
|
Manufacturer and Acceptance
- Manufacturer
- Tremco Ltd.
- Accepted for the RoofStar Guarantee Program
- June 2021
- Accepted for application in
- Roof Waterproofing Systems
- Product Summary
- AlphaGuard MT Base Coat is a one-part, moisture triggered, polyurethane liquid applied product installed in a fully-reinforced application utilizing AlphaGuard Glass Mat or Permafab reinforcements. This product is accepted by the RGC as part of a reinforced 2-coat membrane system.
- (adapted from the Technical Data Sheet)
- Conditions and Limitations
- AlphaGuard MT Base Coat (together with the AlphaGuard MT Top Coat) must be installed by a manufacturer-trained crew under the periodic supervision of the manufacturer's technical representative.
The products must be installed as a new membrane (not as a retrofit product), to a minimum combined wet thickness of 80 mils (minimum dry thickness: 72 mils).
AlphaGuard MT Base and Top Coat may be installed in a conventionally insulated roof system over an RGC-accepted base membrane, or directly to a concrete deck as an un-insulated membrane system or as part of a Protected Membrane Roof System.
|
- Click below for the Technical Data Sheet.