ASM Eave Protection and Underlayment

Jump to: navigation, search

ASM Eave Protection and Underlayment

Revision as of 17:19, 21 December 2015 by James Klassen (talk | contribs) (Created page with "File:8.1.4.1.1.jpg === WORK INCLUDED === ;(1) <b>Underlayment</b>: :Proprietary underlayment installed perpendicular to the slope with 50 mm (2") minimum side laps and 1...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

8.1.jpg

1 WORK INCLUDED

(1) Underlayment
Proprietary underlayment installed perpendicular to the slope with 50 mm (2") minimum side laps and 100 mm (4") minimum end laps.
(2) Ice And Water Protection
One ply of accepted self-adhered modified bituminous membrane.
(3) Edge Metal Flashing
Installed to manufacturer’s printed instructions.
Note
This specification is only applicable to slopes 1
  • 3 (4" in 12") or greater
  • Slip sheet not shown for clarity

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
NOTE: * Refer to RGC Guarantee Standards for additional requirements.


Back to Construction Details