1 WORK INCLUDED

(1) Ice Dam Protection: Accepted self-adhered modified bituminous membrane.

(2) Slip Sheet: Recommended over asphaltic underlays and / or as required by metal panel manufacturer.

(3) Metal Panel Clip: Installed to metal roof panel manufacturer’s printed instructions.

(4) Architectural Metal Roof Panel

(5) Continuous Metal Cleat

(6) Metal Fascia Flashing

(7) Continuous Edge Metal Flashing

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

(B) Wood Nailer

(C) Fascia Board

NOTE: * Refer to RGC Guarantee Standards for additional requirements.