ASM Curb (Split Panel Flashing)
ASM Curb (Split Panel Flashing)
Revision as of 17:26, 21 December 2015 by James Klassen (talk | contribs) (Created page with "File:8.1.4.10.1.jpg === WORK INCLUDED === (1) <b>Underlayment</b>: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2)....")
1 WORK INCLUDED
(1) Underlayment: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).
(2) Slip Sheet: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Metal Panel Clip: Installed to metal roof panel manufacturer’s printed instructions.
(4) Architectural Metal Roof Panel
(5) Metal Curb Flashing
(6) Cricket: Required for curbs more than 900 mm (36") wide
(7) Accepted Caulking: Two rows accepted caulking between overlapping sheets, with preformed closures on trapezoidal ribbed roof panels.
(8) Counter Flashing
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Wood Curb: 200 mm (8") minimum height
NOTE: * Refer to RGC Guarantee Standards for additional requirements.