SBS Fall Protection Anchor in Wall (Protected)

Jump to: navigation, search

SBS Fall Protection Anchor in Wall (Protected)

Revision as of 21:53, 1 September 2021 by James Klassen (talk | contribs)


Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
SBS Details

10.3.7.3.jpg

1 WORK INCLUDED

(1) Inverted (Protected) Roof Assembly
(2) Counter-flashing
(3) Insulation - XPS
See available insulation products in Division C of this Manual.
(4) Primary Membrane

2 RELATED WORK BY OTHERS

(A) Acceptable Supporting Deck Structure
(B) Anchor
Anchor selection and attachment details are the responsibility of the Design Authority.
(C) Anchor Eye
(D) Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants
Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished roof surfacing.
(E) Plywood
15.9 mm (5/8") treated where required.

NOTE: See the Standard for additional requirements.


Back to "SBS" Roof System Details

Home

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.