Division D - Construction Details


WP Details:F1.7.3 (Wearing Course - Concrete Slab)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Waterproofing Details for Plazas, Promenades and Terraces

9.6.3.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane
Fully adhered to acceptable substrates (concrete slab depicted) installed as per the Standard and Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive
proprietary primer or adhesive application method and quantities as directed by membrane membrane manufacturer published application specifications.
(3) Protection Board/Mat
Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with the Standard.
(4) Drainage Medium
Proprietary (purpose-made) geocomposites drainage board, with synthetic water permeable filter fabric mat, designed to provide secondary drainage below poured concrete wearing slabs or unit masonry, pavers, brick or stone set in mortar beds.

2 WORK BY OTHERS

(A) Acceptable Deck
Concrete slab depicted
(B) Wearing Coarse
Concrete slab (depicted) or pavers, bricks or stone set in mortar beds designed to predicted live loads.
(C) Score Line or Indent
pattern set into concrete slab wearing course in order to facilitate cutting at designate sections is mandatory under the Standard.
(D) Conductive Tape
Moisture Survey System (tape grid) mandatory and compliant with the Standard. For Electronic Leak Detection systems recognized by the Guarantor, refer to the Accepted Materials section of this Manual.

NOTE: See the Standard for additional requirements.