Notes to Part 1

Notes to Part 2

Notes to Part 3

Notes to Part 4

Notes to Part 5

Notes to Part 6

Notes to Part 7

A-7.1.3.1 (Responsibility for Design)
Insulation materials rely on various standards for the determination of thermal resistance, which means that not all data can be easily compared. Furthermore, not all insulation products perform with consistent thermal resistance as temperature changes, and some insulation performance declines with age. Therefore, refer to the Long-term Thermal Resistance (LTTR) for each insulation product, in relation to the product's placement within the roof assembly and the anticipated outside and interior climates of the building.
Also see the British Columbia Building Code, Division B, Part 10 (Section 9.25. Heat Transfer, Air Leakage and Condensation Control for structures governed by Part 9), together with relevant requirements in Division A and Division C of the Building Code.
A-7.1.3.2 (Effective Thermal Resistance and Layering)
In warm seasons, the roof surface may reach temperatures higher than 85°C (185°F), affecting the performance and stability of some insulation. Consequently, the requirement which limits panel size in single-layer applications ensures that inevitable gaps between adjacent panels are kept to a minimum. Combining insulation types in a roof system may help mitigate these temperature swings and the consequence of thermal contraction. The Design Authority therefore must consider these variables when specifying materials and their installation.
The Long-Term Thermal Resistance (LTTR) measurement of closed-cell insulation materials remains the standard by which insulation performance is measured. Published R-values should reflect the LTTR of the material. In Canada, two principal standards apply to the accurate measurement of thermal resistance: CAN/ULC-S770 (Standard Test Method for Determination of Long-Term Thermal Resistance of Closed-Cell Thermal Insulating Foams) and CAN/ULC-S704.1 (Standard for Thermal Insulation, Polyurethane and Polyisocyanurate, Boards, Faced).
A-7.1.3.4 (Tapered Insulation and Crickets)
The effective thermal resistance of any insulation is dependent on location and other intervening factors (penetrating screw fasteners, for example) which may diminish the performance of the insulation panel. Effective thermal resistance of sloped or tapered insulation is not the same as the average value, using the minimum and maximum thermal resistance of a panel. For help with these calculations, use the RoofStar Effective Thermal Resistance Calculator for Sloped Insulation.

Notes to Part 8

A-8.1 (Design)
Insulation overlay boards are installed in most conventionally insulated systems to
  • protect heat-sensitive insulation materials from damage by heat and flame.
  • protect insulation materials from accidental impact.
  • provide dimensional stability to the roof system.
  • distribute dead loads from heavy overburdens or equipment installed on top of the finished waterproofing system.
  • ensure the membrane performs as it should.
  • provide a suitable substrate for membrane application.
Insulation overlay boards may be mechanically attached or adhered, depending upon the insulation type and the design requirements of the entire roof assembly.

Notes to Part 9

A-9.1.2.2 (All Projects - Membrane Protection)
Sunlight reflected from windows, doors, cladding and other reflective materials can elevate roof surface and sub-surface temperatures, which may shorten the life of a membrane and the roof system materials beneath it, and may cause irreparable damage. Roofs oriented to face south and southwest are particularly vulnerable to these effects, and sunlight reflected from metal can be more damaging than light reflected by glass.
For more about this phenomenon, read The Impact of Solar Reflectivity of Glazing Adjacent Roofs, published in the Summer 2021 issue of RoofingBC.