Asphalt Shingles - Application (Common and Steep Slopes)

Jump to: navigation, search

Asphalt Shingles - Application (Common and Steep Slopes)

Revision as of 18:21, 29 June 2022 by James Klassen (talk | contribs)



Division D - Construction Details


Asphalt Shingles | Application (Common and Steep Slopes) ( Article 6.3.2.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

Asphalt Shingle Details

Applicable to slopes 1:3 (4" in 12") and greater. 7.1.2.1.1.jpg

1 WORK INCLUDED

(1) Eave Protection
One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection. Lap 75 mm (3") minimum on sides and 150 mm (6") minimum on ends.
(2) Underlayment
Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
(3) Edge Metal Flashing
Required for all eave and rake edges.
(4) Starter Course
Standard strip, laminated or architectural shingle starter course consists of proprietary starter shingles or (in the case of strip shingles) the same type shingles used in the field. Install according to requirements in Subsection 9.3.1 General, together with the Manufacturer's printed application instructions.
(5) Standard Strip, Laminated or Architectural Shingles
Applied as recommended by manufacturer.
(6) Nailing
See the requirements in Section 3.3 Application.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.


Back to Asphalt Shingle System Details

Home

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.