SBS Details
1 WORK INCLUDED
- (1) Base sheet membrane flashing
- Waterproofs the expansion joint structure and provides a base layer for the control joint to bond material to bond with.
- (2) Expansion joint (elastomeric product illustrated)
- This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed, or supervised, by others. Secure to substrate as required by manufacturer.
- (3) Reinforced membrane strip
- Applied to cover the control joint and seal it to the base membrane system.
- (4) Cap sheet membrane flashing
- Installed as required in Part 10 and applied as the second or third of a two or three-ply membrane system, providing required coverage above the finished roof system surface. Smooth membrane is shown on parapet coping (may be granule-surfaced, depending on material specified).
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
- (B) Expansion joint structure
- (C) Finished wall assembly
NOTE: See the Standard for additional requirements.