Click on a manufacturer's name to see the full list of their vegetated roof systems accepted for use in the RoofStar Guarantee Program. Click on the System Name to see the materials and documentation for the system.
To reset this page to its original view, click your browser refresh button.
VRS Supplier VR System Name * VRS Type System
Min.
Depth
mm (in)
System
Max.
Depth
mm (in)
Media
Min.
Depth
mm (in)
Media
Max.
Depth
mm (in)
Carlisle SynTec Systems Canada Carlisle Extensive Roof Garden System Extensive 101.6 (4) 127 (5) 70 (1-1/4) 127 (5)
Carlisle SynTec Systems Canada Carlisle Roof Garden Extensive Stormwater Retention System Extensive 140 (5-1/2) 140 (5-1/2) 101.6 (4) 101.6 (4)
Carlisle SynTec Systems Canada Carlisle Semi-Intensive Roof Garden System Semi-intensive 158.8 (6-1/4) 235 (9-1/4) 127 (5) 203.2 (8)
Carlisle SynTec Systems Canada Carlisle Intensive Roof Garden System Intensive 235 (9-1/4) None Stated 203.2 (8) None Stated
Hydrotech Membrane Corporation Hydrotech Extensive Garden Roof Assembly Extensive 101.6 (4) 203.2 (7) 76.2 (3) 152.4 (6)
Hydrotech Membrane Corporation Hydrotech Semi-intensive Garden Roof Assembly Semi-intensive 203.2 (8) 355.6 (14) 152.4 (6) 304.8 (12)
Hydrotech Membrane Corporation Hydrotech Intensive Garden Roof Assembly Intensive 355.6 (14) 939.8 (37) 304.8 (12) 889 (35)
Next Level Stormwater Management NLSM LiteN'Less Extensive 40.7 (1-5/8) 64.0 (2-1/2) 25.4 (1) 25.4 (1)
Next Level Stormwater Management NLSM LiteN'Less II Extensive 30.7 (1-1/8) 30.7 (1-1/8) 20 (13/16) 20 (13/16)
Next Level Stormwater Management NLSM LiteN'Less III Extensive 45.0 (1-13/16) 62.0 (2-7/16) 20 (13/16) 20 (13/16)
Next Level Stormwater Management NLSM TerraEXT Extensive 113.0 (4-13/16) 188 (7-13/16) 95.0 (3-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM StormCap Extensive 114 (4-1/2) 264 (10-3/8) 70 (2-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM StormCap Detain 3° Extensive 114 (4-1/2) 352 (13-7/8) 70 (2-3/4) 170 (6-11/16)
Next Level Stormwater Management NLSM Eco-Grass Semi-intensive 188 (7-7/16) 338 (13-5/16) 170 (6-11/16) 320 (12-9/16)
Next Level Stormwater Management NLSM Flora Garden Intensive 162 (6-3/8) 312 (12-5/16) 150.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Extensive-Conv. Veg. Roof Extensive 85.85 (3-3/8) 162 (6-3/8) 76.2 (3) 152.4 (6)
Soprema Inc. SOPRANATURE® Extensive-Inverted Veg. Roof Extensive 88.1 (3-6/16) 164.3 (6-6/16) 76.3 (3) 152.4 (6)
Soprema Inc. SOPRANATURE® Modular-Conv. Veg. Roof Extensive 100.5 (3-15/16) 100.5 (3-15/16) 100 (3-7/8) 100 (3-7/8)
Soprema Inc. SOPRANATURE® Modular-Inverted Veg. Roof Extensive 100.5 (3-15/16) 100.5 (3-15/16) 100 (3-7/8) 100 (3-7/8)
Soprema Inc. SOPRANATURE® Semi-Intensive-Inverted Veg. Roof Semi-intensive 164.3 (6-6/16) 316.7 (12-6/16) 152.4 (6) 304.8 (12)
Soprema Inc. SOPRANATURE® Intensive-Inverted Veg. Roof Intensive 361.7 (12-6/16) 361.7 (12-6/16) + 304.8 (12) 304.8 (12) +
Soprema Inc. SKYWATER® Ballasted-Inverted Hybrid Roof Hybrid 107.9 (4-1/4) 336.5 (13-1/4) + 76.3 (3) 304.8 (12) +
Soprema Inc. SKYWATER® SOPRAFLOW CONTROL Hybrid 136.9 (5-3/8) 265.2 (14-3/8) 76.3 (3) 304.8 (12) +
* Click on the Vegetated Roof Name to link to the system page for specified or optional vegetation profiles
Vegetated roof systems can be divided into three classic types: Extensive, Semi-intensive, and Intensive. Added to this are blue-green roofs, also referred to as "hybrid systems." Refer to the Notes to the Notes to the Standard for Vegetated Roofs for an expanded treatment on the three principal types. To learn more about RGC requirements for hybrid systems, see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
Minimum system and growing media depths may vary. For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements. This may affect the minimum thickness of a system. Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture). Always refer to the system page for more information.