SBS Fall Protection Anchor in Wall (Protected)
SBS Fall Protection Anchor in Wall (Protected)
Revision as of 16:19, 19 July 2016 by James Klassen (talk | contribs) (Created page with "File:10.3.7.3.jpg === WORK INCLUDED === (1) <b>Inverted Roof Assembly</b> (2) <b>Metal Counter Flashing</b> (3) <b>Insulation:</b> Extruded Polystyrene (4) <b>Primary...")
1 WORK INCLUDED
(1) Inverted Roof Assembly
(2) Metal Counter Flashing
(3) Insulation: Extruded Polystyrene
(4) Primary Membrane
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Anchor to CSA Z91-M90: Poured concrete shown, see anchor manufacturer’s attachment for other wall types and attachment methods
(C) Anchor Eye to CSA Z91-M90
(D) Anchor Placement For Roof Decks Accessible By General Public/Residential Occupants: Maximum 100 mm (4") above finished roof surface (design to prevent climbing) and not less than 3-1/2" above the finished roof surfacing.
(E) Plywood: 15.9 mm (5/8") treated where required.
NOTE: Refer to RGC Guarantee Standards for additional requirements.