ASM Roof-Wall Connection (Head-wall, Vented)
ASM Roof-Wall Connection (Head-wall, Vented)
1 WORK INCLUDED
(1) Underlayment: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).
(2) Slip Sheet: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Architectural Metal Roof Panel: Turned up (bread panned) at termination.
(4) Metal Roof Panel Clip: installed to metal roof manufacturer’s printed instructions
(5) ‘Z’ Closure: set in accepted caulking and secured with compatible, non-corrosive flat head fasteners.
(6) Manufactured plastic louvres:
(7) Exposed Fastener: High domed, gasketed cladding type screw compatible with metal roof panel (see Section 8.1.4.1 and 8.1.4.2).
(8) Metal Base Flashing: Must extend 200 mm (8") over metal roof panel. Lap joints must be sealed with two rows of accepted caulking. Exposed edges to be turned under.
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Wood Nailer
(C) Free Vent Area
(D) Wall
(E) Building Paper
NOTE: Refer to RGC Guarantee Standards for additional requirements.