SBS Parapet (Typical)

Jump to: navigation, search

SBS Parapet (Typical)

Revision as of 21:05, 29 July 2016 by James Klassen (talk | contribs) (WORK INCLUDED)

10.3.1.1.jpg

1 WORK INCLUDED

Gypsum Board
If required by design authority.
Vapour Retarder
If required by design authority.
Insulation
See list of Accepted Materials.
Insulation Overlay Board
As required.
Primary Membrane and Membrane Protection
Membrane Flashing
Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge.
Metal Base Flashing
Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
Metal Cap Flashing
Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams.

2 RELATED WORK BY OTHERS

(A) Acceptable Steel Deck
(B) Air/Vapour Seal
(C) Acceptable Wall Surface
(D) Wood Blocking
(E) Sloped Wood Blocking
Required over 100 mm (4") parapet width.


NOTE: Refer to RGC Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details