SBS Fall Protection Anchor in Roof

Jump to: navigation, search

SBS Fall Protection Anchor in Roof

Revision as of 21:30, 5 August 2016 by James Klassen (talk | contribs) (WORK INCLUDED)

10.3.7.1.jpg

1 WORK INCLUDED

(1) Flashing
0.08 mm (0.032", 20 gauge) Aluminum or 0.56 mm (16 oz) copper to CSA B272-93 flashing supplied by anchor manufacturer with flanges sealed by roofer.
(2) Flashing Flange
minimum 100 mm (4") flange set in coating of compatible sealant.
(3) Primary Membrane and Membrane Flashing
(4) Protected Membrane Roof Assembly
Flashing to extend a minimum 200 mm (8") above finished roof surface (pavers, ballast, or walkways)
(5) Conventional Roof Assembly
Flashing to extend a minimum 200 mm (8") above finished roof surface.
(6) Insulation
See available insulation products in the Accepted Materials section of this Manual.

2 WORK BY OTHERS

(A) Acceptable Deck
Concrete slab shown, see anchor manufacturer's attachment details for other deck types.
(B) Roof Anchor
to CSA Z91-M90
(C) Anchor Eye
to CSA Z91-M90
(D) Water Tight Cap


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details