EPDM Details:D2.7.7-2 Strip-in Flashings (Two-part Cable)

Jump to: navigation, search

EPDM Details:D2.7.7-2 Strip-in Flashings (Two-part Cable)

Revision as of 16:10, 21 September 2016 by James Klassen (talk | contribs)
RoofStar Guarantee Standards are blue-linked
EPDM Details

FOR USE WHEN DISCONNECT OF CABLES OR PIPES IS IMPRACTICAL

6.3.6.1.jpg

1 WORK INCLUDED

1) Gypsum Deck Overlay
May be required depending on insulation thickness or when required as a thermal barrier by design authority.
(2) Vapour Retarder
If required by design authority.
(3) Insulation
Mechanically attached. Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
(4) Single-ply Membrane
Installed according to manufacturer's instructions and RoofStar Guarantee Standards.
(5) Mastic
Compatible mastic or sealant.
(6) Membrane Flashing
Adhered according to manufacturer's printed specifications using proprietary adhesive. Thermoset membrane may be joined using uncured tape or proprietary adhesive (See Section 6.1).

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Wood Blocking
(C) Two Piece Flashing
Assembled around protrusion, laid over compatible sealant on top of primary membrane. Mechanically fasten two components together and fasten flange to wood blocking or deck.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.