SBS Expansion Joint (Wall)
SBS Expansion Joint (Wall)
Division D - Construction Details
SBS | Expansion Joint (Wall) ( Article 10.3.6.1.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
SBS Details
1 WORK INCLUDED
- (1) Base sheet membrane flashing
- Waterproofs the expansion joint structure and provides a base layer for the control joint to bond material to bond with.
- (2) Expansion joint (elastomeric product illustrated)
- This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed, or supervised, by others. Secure to substrate as required by manufacturer.
- (3) Reinforced membrane strip
- Applied to cover the control joint and seal it to the base membrane system.
- (4) Cap sheet membrane flashing
- Installed as required in Part 10 and applied as the second or third of a two or three-ply membrane system, providing required coverage above the finished roof system surface. Smooth membrane is shown on parapet coping (may be granule-surfaced, depending on material specified).
2 RELATED WORK BY OTHERS
- (A) Acceptable deck
- (B) Expansion joint structure
- (C) Finished wall assembly
NOTE: See the Standard for additional requirements.
Back to "SBS" Roof System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.