WP Details:F1.7.7 (Walls - Low Door Sill)

Jump to: navigation, search

WP Details:F1.7.7 (Walls - Low Door Sill)



Division D - Construction Details


WP Details:F1.7.7 (Walls - Low Door Sill)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Waterproofing Details for Plazas, Promenades and Terraces

9.6.7.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane
Fully adhered to acceptable substrates.
(2) Membrane Flashing
At walls membrane flashing must be carried up walls a minimum of 100mm (4") in height above the finished waterproofing assembly be it ballast, pavers or other permeable wearing course. At door sill openings membrane flashing may be less than 100mm (4") in height above the finished waterproofing assembly but must not be less than 100mm (4") in height above the primary waterproofing membrane. Low door sills shall incorporate a metal water stop flashing that is mechanically attached to the backside of door sill framing or openings and is sealed with elastomeric or SBS membrane flashing. In addition, membrane flashing gussets must be installed at door sill opening corners. For additional requirements refer to Section 7, Perimeter Flashing: Membranes.
(3) Metal Base Flashing
Required on all waterproofing assemblies. Flashing lengths joined by use of S-locks or standing seam joints.
(4) Metal Counter Flashing
Extend behind wall finish (siding) minimum 50mm (2"). Flashing lengths joined by use of S-locks or standing seam joints.
(5) Metal Water Stop Flashing
Mechanically attached to inside of door sill framing or opening. Cut flashing to fit opening and install membrane gussets at corners.
(6) Metal Pan Sill Flashing
Optional: Metal pan with water stop formed with pan folded, welded or soldered corners mechanically attached to inside of door sill frame or opening and sealed with membrane flashing.
(7) [[Grade-level Waterproofing Standard#WPPROTECTION | Protection Board/Mat]
Proprietary membrane protection board or mat approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with Section 8, Membrane Protection.

2 WORK BY OTHERS

(A) Acceptable Deck
Concrete slab depicted.
(B) Wall Cladding and Flashing

NOTE: See the Standard for additional requirements.