Difference between revisions of "ASM 10.4.4 Ridge (Snap Seam, Notched)"

Jump to: navigation, search

Difference between revisions of "ASM 10.4.4 Ridge (Snap Seam, Notched)"

 
(2 intermediate revisions by the same user not shown)
Line 13: Line 13:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
+
;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
 
;(2) '''Insulation Overlay Protection''': Recommended.  
 
;(2) '''Insulation Overlay Protection''': Recommended.  
;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination.  
+
;(3) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination.  
 
;(4) ''''Z'-Bar''': Installed to meet adequate attachment for UL I-90 wind uplift requirements.  
 
;(4) ''''Z'-Bar''': Installed to meet adequate attachment for UL I-90 wind uplift requirements.  
;(5) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMINS |'''Insulation''']]:  Installed between &#8216;Z&#8217; bars or wood battens on 600 mm (24") centres.  
+
;(5) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMINS |'''Insulation''']]:  Installed between &#8216;Z&#8217; bars or wood battens on 600 mm (24") centres.  
;(6) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Foam Closures''']]: Set in accepted caulking.  
+
;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLOSURE |'''Pre-formed Foam Closures''']]: Set in accepted caulking.  
;(7) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMEXFASTEN |'''Exposed Fasteners''']]: High domed, gasketed cladding type screws compatible with metal roof panel.  
+
;(7) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMEXFASTEN |'''Exposed Fasteners''']]: High domed, gasketed cladding type screws compatible with metal roof panel.  
 
;(8) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").  
 
;(8) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").  
;(9) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDRAG |'''Drag-load Fasteners''']]: Compatible non-corrosive fasteners.  
+
;(9) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDRAG |'''Drag-load Fasteners''']]: Compatible non-corrosive fasteners.  
  
 
<hr>
 
<hr>
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
+
;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
Line 36: Line 36:
  
  
 
+
[[RoofStar Guarantee Standards for ASM Roof Assemblies|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for ASM Roof Assemblies]]
[[RoofStar Guarantee Standards for ASM Roof Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for ASM Roof Systems]]
 
  
 
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
 
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
+
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Latest revision as of 16:27, 26 April 2019

RoofStar Guarantee Standards are blue-linked
ASM Details

8.1.4.12.1.jpg

1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Insulation Overlay Protection
Recommended.
(3) Architectural Metal Roof Panel 
Turn up (bread panned) at termination.
(4) 'Z'-Bar
Installed to meet adequate attachment for UL I-90 wind uplift requirements.
(5) Insulation
Installed between ‘Z’ bars or wood battens on 600 mm (24") centres.
(6) Pre-formed Foam Closures
Set in accepted caulking.
(7) Exposed Fasteners
High domed, gasketed cladding type screws compatible with metal roof panel.
(8) Metal Cap Flashing
Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").
(9) Drag-load Fasteners
Compatible non-corrosive fasteners.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for ASM Roof Assemblies

Back to ASM Construction Details

Back to Construction Details