;(1) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#ASEAVE|'''Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection.  Lap 50 mm (2") minimum on sides and 150 mm (6") minimum on ends.  Refer also to [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#LSEAVE|'''2.2.2 Eave Protection / Underlay''']].
+
;(1) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#ASEAVE|'''Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection.  Lap 50 mm (2") minimum on sides and 150 mm (6") minimum on ends.  Refer also to [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#LSEAVE|'''2.2.2 Eave Protection / Underlay''']].
;(2) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#ASUNDERLAYMENT|'''Underlayment''']]: Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
+
;(2) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#ASUNDERLAYMENT|'''Underlayment''']]: Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
;(3) '''Edge Metal Flashing''': Optional (cf. [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#ASLSEDGE|'''1.2.10 Wood Deck Overlay Sheathing (Non-Structural)''']] for specific requirements), installed to manufacturer's printed instructions.
+
;(3) '''Edge Metal Flashing''': Optional (cf. [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#ASLSEDGE|'''1.2.10 Wood Deck Overlay Sheathing (Non-Structural)''']] for specific requirements), installed to manufacturer's printed instructions.
;(4) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#ASSTARTER|'''Starter Course''']]: '''Standard Strip and interlocking shingles''' starter course consist of same type shingles as for roof, applied tabs facing up the slope. Laminated shingle starter courses consist of Manufacturer's proprietary starter shingles or same type shingle with the exposed (bottom) portion cut off below the seal strip. Apply to Manufacturer's printed application instructions.
+
;(4) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#ASSTARTER|'''Starter Course''']]: '''Standard Strip and interlocking shingles''' starter course consist of same type shingles as for roof, applied tabs facing up the slope. Laminated shingle starter courses consist of Manufacturer's proprietary starter shingles or same type shingle with the exposed (bottom) portion cut off below the seal strip. Apply to Manufacturer's printed application instructions.
 
;(5) '''Standard Strip, Laminated or Interlocking Shingles''': Applied as recommended by manufacturer.
 
;(5) '''Standard Strip, Laminated or Interlocking Shingles''': Applied as recommended by manufacturer.
;(6) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#ASNAILING|'''Nailing''']]: Note manufacturer's recommended nailing pattern. Placement varies with manufacturer.
+
;(6) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#ASNAILING|'''Nailing''']]: Note manufacturer's recommended nailing pattern. Placement varies with manufacturer.
  
 
<hr>
 
<hr>
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems#ASDECK|'''Acceptable Deck''']]
+
;(A) [[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies#ASDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
Line 30: Line 30:
  
 
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
 
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
 
  
 
<hr>
 
<hr>
  
  
 
+
[[RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies]]
[[RoofStar Guarantee Standards for Asphalt Shingles Roof Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingles Roof Systems]]
 
  
 
[[Asphalt Shingles Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
 
[[Asphalt Shingles Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
+
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 17:42, 23 October 2017

RoofStar Guarantee Standards are blue-linked
Asphalt Shingle Details

Applicable to slopes 1:3 (4" in 12") and greater. 7.1.2.1.1.jpg

1 WORK INCLUDED

(1) Eave Protection
One ply of self-adhered modified bituminous underlayment material or other acceptable eaves protection. Lap 50 mm (2") minimum on sides and 150 mm (6") minimum on ends. Refer also to 2.2.2 Eave Protection / Underlay.
(2) Underlayment
Minimum one ply of No. 15 non-perforated asphalt saturated felt or accepted eaves protection. Overlap 50 mm (2") minimum on side laps and 150 mm (6") minimum on end laps.
(3) Edge Metal Flashing
Optional (cf. 1.2.10 Wood Deck Overlay Sheathing (Non-Structural) for specific requirements), installed to manufacturer's printed instructions.
(4) Starter Course
Standard Strip and interlocking shingles starter course consist of same type shingles as for roof, applied tabs facing up the slope. Laminated shingle starter courses consist of Manufacturer's proprietary starter shingles or same type shingle with the exposed (bottom) portion cut off below the seal strip. Apply to Manufacturer's printed application instructions.
(5) Standard Strip, Laminated or Interlocking Shingles
Applied as recommended by manufacturer.
(6) Nailing
Note manufacturer's recommended nailing pattern. Placement varies with manufacturer.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for Asphalt Shingles Roof Assemblies

Back to Asphalt Shingles Construction Details

Back to Construction Details