Difference between revisions of "Asphalt Shingles - Intersection with Waterproofing Roof (Upper)"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingles - Intersection with Waterproofing Roof (Upper)"

(WORK INCLUDED)
 
(11 intermediate revisions by the same user not shown)
Line 1: Line 1:
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
+
{{Template:RPM Info}}
| colspan="2| <big>'''''RoofStar Guarantee Standards''''' are <span style="color:#6495ed">'''blue-linked'''</span></big>
+
 
|}
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
 +
 
 +
<big><big>Division D - Construction Details</big></big>
 +
<hr>
 +
<big><big><big><big><big>Asphalt Shingles | Intersection with Waterproofing Roof (Upper) ([[Asphalt_Shingle_Systems_Standard#10.3.7.2. Intersections with Waterproofing Roof Systems | Article 10.3.7.2.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 
<div class="panel panel-success">
 
<div class="panel panel-success">
 
<div class="panel-heading"><big>'''Asphalt Shingle Details'''</big></div>
 
<div class="panel-heading"><big>'''Asphalt Shingle Details'''</big></div>
Line 11: Line 17:
 
|+ Click on any image to expand it
 
|+ Click on any image to expand it
 
|-
 
|-
| [[File:ASh 10.7.1-1 CD.jpg | class=img-responsive | link=http://rpm.rcabc.org/images/e/ef/ASh_10.5.1-1_CD.jpg]]
+
| [[File:ASh Intersection with Waterproofing Roof (Upper) 1.jpg | link=https://rpm.rcabc.org/images/b/b8/ASh_Intersection_with_Waterproofing_Roof_%28Upper%29_1.jpg | class=img-responsive]]
 
|-
 
|-
| [[File:ASh 10.7.1-2 CD.jpg | class=img-responsive | link=http://rpm.rcabc.org/images/e/ed/ASh_10.5.1-3_CD.jpg]]  
+
| [[File:ASh Intersection with Waterproofing Roof (Upper) 2.jpg | link=https://rpm.rcabc.org/images/8/81/ASh_Intersection_with_Waterproofing_Roof_%28Upper%29_2.jpg | class=img-responsive]]  
 
|}
 
|}
 
</div>
 
</div>
Line 20: Line 26:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShUNDERLAYMENT|'''Underlayment''']]: Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing.  Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
+
;(1) [[Asphalt Shingle Systems Standard#AShUNDERLAYMENT|'''Underlayment''']]: Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing.  Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
;(2) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShEAVES|'''Eave Protection Membrane''']]: Applied beneath the metal valley flashing.
+
;(2) [[Asphalt Shingle Systems Standard#AShEAVES|'''Eave Protection Membrane''']]: Applied beneath the metal valley flashing.
;(3) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFIELDAPPLICATION|'''Shingles (field)''']]:
+
;(3) [[Asphalt Shingle Systems Standard#AShPART9GEN-APPLICATION|'''Shingles (field)''']]:
;(4) Metal Counterflashing.
+
;(4) Metal Counterflashing/Headwall Flashing.
 
;(5) Metal Edge Flashing: (refer to the related Membrane Standards, '''10.3.5.2 Metal Edge Terminations''').
 
;(5) Metal Edge Flashing: (refer to the related Membrane Standards, '''10.3.5.2 Metal Edge Terminations''').
 
;(6) Field Membrane: (refer to the related Membrane Standards, Part '''9 FIELD MEMBRANE''' and Part '''10 PERIMETERS and WALLS''').
 
;(6) Field Membrane: (refer to the related Membrane Standards, Part '''9 FIELD MEMBRANE''' and Part '''10 PERIMETERS and WALLS''').
Line 30: Line 36:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShDECK|'''Acceptable Deck''']]
+
;(A) [[Asphalt Shingle Systems Standard#AShDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL -->
 
</div><!-- PANEL -->
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
'''NOTE''': See the [[Asphalt Shingle Systems Standard | '''Standard''']] for additional requirements.
  
 
<hr>
 
<hr>
  
 +
[[Asphalt Shingle System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingle System Details'']]
  
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
 
 
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
 
  
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 14:13, 5 October 2022



Division D - Construction Details


Asphalt Shingles | Intersection with Waterproofing Roof (Upper) ( Article 10.3.7.2.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

Asphalt Shingle Details
Click on any image to expand it
ASh Intersection with Waterproofing Roof (Upper) 1.jpg
ASh Intersection with Waterproofing Roof (Upper) 2.jpg

1 WORK INCLUDED

(1) Underlayment
Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing. Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
(2) Eave Protection Membrane
Applied beneath the metal valley flashing.
(3) Shingles (field)
(4) Metal Counterflashing/Headwall Flashing.
(5) Metal Edge Flashing
(refer to the related Membrane Standards, 10.3.5.2 Metal Edge Terminations).
(6) Field Membrane
(refer to the related Membrane Standards, Part 9 FIELD MEMBRANE and Part 10 PERIMETERS and WALLS).

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: See the Standard for additional requirements.


Back to Asphalt Shingle System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.