Difference between revisions of "Asphalt Shingles - Intersection with Waterproofing Roof (Upper)"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingles - Intersection with Waterproofing Roof (Upper)"

Line 20: Line 20:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShUNDERLAYMENT|'''Underlayment''']]: Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing.  Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
+
;(1) [[Standard for Asphalt Shingle Systems#AShUNDERLAYMENT|'''Underlayment''']]: Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing.  Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
;(2) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShEAVES|'''Eave Protection Membrane''']]: Applied beneath the metal valley flashing.
+
;(2) [[Standard for Asphalt Shingle Systems#AShEAVES|'''Eave Protection Membrane''']]: Applied beneath the metal valley flashing.
;(3) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShFIELDAPPLICATION|'''Shingles (field)''']]:
+
;(3) [[Standard for Asphalt Shingle Systems#AShPART9GEN-APPLICATION|'''Shingles (field)''']]:
 
;(4) Metal Counterflashing.
 
;(4) Metal Counterflashing.
 
;(5) Metal Edge Flashing: (refer to the related Membrane Standards, '''10.3.5.2 Metal Edge Terminations''').
 
;(5) Metal Edge Flashing: (refer to the related Membrane Standards, '''10.3.5.2 Metal Edge Terminations''').
Line 30: Line 30:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for Asphalt Shingle Systems#AShDECK|'''Acceptable Deck''']]
+
;(A) [[Standard for Asphalt Shingle Systems#AShDECK|'''Acceptable Deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
Line 40: Line 40:
  
  
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
+
[[Standard for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> Standard for Asphalt Shingle Systems]]
  
 
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
 
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
  
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 16:50, 8 June 2021

RoofStar Guarantee Standards are blue-linked
Asphalt Shingle Details
Click on any image to expand it
link=http://rpm.rcabc.org/images/e/ef/ASh 10.7.1-1 CD.jpg
link=http://rpm.rcabc.org/images/e/ed/ASh 10.7.1-2 CD.jpg

1 WORK INCLUDED

(1) Underlayment
Required, and installed to overlap the Valley Protection Membrane and the Valley Metal Flashing. Install ‘shingle-style’, following the requirements for side and end laps; use acceptable fasteners, or adhere (if a self-adhering membrane) in keeping with the manufacturer’s published requirements.
(2) Eave Protection Membrane
Applied beneath the metal valley flashing.
(3) Shingles (field)
(4) Metal Counterflashing.
(5) Metal Edge Flashing
(refer to the related Membrane Standards, 10.3.5.2 Metal Edge Terminations).
(6) Field Membrane
(refer to the related Membrane Standards, Part 9 FIELD MEMBRANE and Part 10 PERIMETERS and WALLS).

2 RELATED WORK BY OTHERS

(A) Acceptable Deck

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



Standard for Asphalt Shingle Systems

Back to Asphalt Shingles Construction Details

Back to Construction Details