Asphalt Shingles - Changes in Slope (Outside Angle)
Asphalt Shingles - Changes in Slope (Outside Angle)
(Redirected from Asphalt Shingles Changes in Slope (Outside Angle))
Division D - Construction Details
Asphalt Shingles | Changes in Slope (Outside Angle) ( Article 9.3.2.7.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
Asphalt Shingle Details
1 WORK INCLUDED
- (1) Underlayment
- Underlayment on the upper slope must overlap the metal transition flashing and lower slope underlayment.
- (2) Self-adhered (eave protection) Membrane
- Optional for this slope change configuration, to seal the upper edge of the metal transition flashing. When installed, the SA membrane must overlap the metal by at least 50 mm (2”) and extend upslope past the edge of the lower slope underlayment by at least 50 mm (2”).
- (3) Metal Transition Flashing
- The lower leg must measure at least 100 mm (4”); the upper leg should measure at least 125 mm (5”).
- (4) Starter Shingle
- (5) Shingle
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: See the Standard for additional requirements.
Back to Asphalt Shingle System Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.