Difference between revisions of "EPDM Details:D2.7.7-2 Strip-in Flashings (Two-part Cable)"
Difference between revisions of "EPDM Details:D2.7.7-2 Strip-in Flashings (Two-part Cable)"
(Created page with "'''NOTE''': This page is under construction. Refer to the '''SBS Membrane Construction Details''' for similar application illustrations and requi...") |
|||
Line 1: | Line 1: | ||
− | ''' | + | <strong>FOR USE WHEN DISCONNECT OF CABLES OR PIPES IS IMPRACTICAL</strong> |
+ | |||
+ | <hr> | ||
+ | [[File:6.3.6.1.jpg]] | ||
+ | |||
+ | |||
+ | |||
+ | === WORK INCLUDED === | ||
+ | ;1) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. | ||
+ | ;(2) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMVAPOUR|'''Vapour Retarder''']]: If required by design authority. | ||
+ | ;(3) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMINSULATION|'''Insulation''']]: Mechanically attached. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. | ||
+ | ;(4) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMMEMBRANE|'''Single-ply Membrane''']]: Installed according to manufacturer's instructions and ''RoofStar Guarantee Standards''. | ||
+ | ;(5) '''Mastic''': Compatible mastic or sealant. | ||
+ | ;(6) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMSTRIPPING|'''Membrane Flashing''']]: Adhered according to manufacturer's printed specifications using proprietary adhesive. Thermoset membrane may be joined using uncured tape or proprietary adhesive (See Section 6.1). | ||
+ | |||
+ | <hr> | ||
+ | |||
+ | === RELATED WORK BY OTHERS === | ||
+ | ;(A) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMDECKS|'''Acceptable Deck''']] | ||
+ | ;(B) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMWOODBLOCKING|'''Wood Blocking''']] | ||
+ | ;(C) '''Two Piece Flashing''': Assembled around protrusion, laid over compatible sealant on top of primary membrane. Mechanically fasten two components together and fasten flange to wood blocking or deck. | ||
+ | |||
+ | |||
+ | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. | ||
Line 7: | Line 30: | ||
− | [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa | + | [[Section:D. Application: Low Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Application'']] |
− | [[EPDM (Thermoset Membranes) Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[EPDM (Thermoset Membranes) Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Construction Details'']] |
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 18:20, 8 August 2016
FOR USE WHEN DISCONNECT OF CABLES OR PIPES IS IMPRACTICAL
1 WORK INCLUDED
- 1) Gypsum Deck Overlay
- May be required depending on insulation thickness or when required as a thermal barrier by design authority.
- (2) Vapour Retarder
- If required by design authority.
- (3) Insulation
- Mechanically attached. Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
- (4) Single-ply Membrane
- Installed according to manufacturer's instructions and RoofStar Guarantee Standards.
- (5) Mastic
- Compatible mastic or sealant.
- (6) Membrane Flashing
- Adhered according to manufacturer's printed specifications using proprietary adhesive. Thermoset membrane may be joined using uncured tape or proprietary adhesive (See Section 6.1).
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Wood Blocking
- (C) Two Piece Flashing
- Assembled around protrusion, laid over compatible sealant on top of primary membrane. Mechanically fasten two components together and fasten flange to wood blocking or deck.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.