Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"

Jump to: navigation, search

Difference between revisions of "SBS Plumbing Vent (Conventional Roof System)"

Line 28: Line 28:
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
 
;(A) [[SBS Roof Systems Standard#SBSDECKS|'''Acceptable Supporting Deck Structure''']]
 
;(A) [[SBS Roof Systems Standard#SBSDECKS|'''Acceptable Supporting Deck Structure''']]
;(B) '''Plumbing Stack''': Extend to match top of metal flashing.
+
;(B) '''Plumbing Stack''': Extend to match top of metal flashing.  Aluminum flashings are required for torch-applied roof systems.
 
;(C) '''Wood Blocking''': Optional.
 
;(C) '''Wood Blocking''': Optional.
 
;(D) [[SBS Roof Systems Standard#SBSPENETRATIONFLASHING|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
 
;(D) [[SBS Roof Systems Standard#SBSPENETRATIONFLASHING|'''Metal Flashing''']]: Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
Line 38: Line 38:
 
</div><!-- PANEL -->
 
</div><!-- PANEL -->
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
'''NOTE''': See the [[SBS Roof Systems Standard | '''Standard''']] for additional requirements.
* Aluminum flashings required for torch-applied roof systems.
 
  
 
<hr>
 
<hr>
  
 +
[[SBS Roof Systems Standard|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies'']]
  
[[SBS Roof Systems Standard |<i class="fa fa-chevron-circle-left fa" ></i> Back to ''RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies'']]
+
[[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''SBS Modified Bitumen Construction Details'']]
  
[[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''SBS Modified Bitumen Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Revision as of 17:51, 27 August 2021


RoofStar Guarantee Standards are blue-linked
SBS Details

10.3.5.5.jpg

1 WORK INCLUDED

(1) Supporting Deck Overlay
If required by design authority.
(2) Air or Vapour Control Layers
If required by design authority.
(3) Insulation
Mechanically fastened. See available insulation products in the Accepted Materials section of this Manual.
(4) Insulation Overlay
(5) Primary Membrane and Membrane Protection
(6) Mastic
As approved by manufacturer.
(7) Membrane Flashing
Onto primed metal flashing flange or adhesive coated for non-bituminous flexible membrane systems.
(8) Storm Collar, Typical Lead Cap or Typical Aluminum Cap
Re-roofing only. Non- bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamps for use with pipes that extend above flashing.

2 RELATED WORK BY OTHERS

(A) Acceptable Supporting Deck Structure
(B) Plumbing Stack
Extend to match top of metal flashing. Aluminum flashings are required for torch-applied roof systems.
(C) Wood Blocking
Optional.
(D) Metal Flashing
Apply in a bed of mastic. Fastened over membrane to wood blocking or roof deck.
(E) Typical Aluminum Cap
For use with aluminum flashing. See requirements for Settlement Caps on strip-in plumbing flashings.
(F) Typical Lead Cap
For use with lead flashing.
(G) Storm Collar
Non-Bituminous flexible membrane skirt collar, sealed with compatible sealant and stainless steel hose clamp. Use with pipes that extend above flashings.

NOTE: See the Standard for additional requirements.


Back to RoofStar Guarantee Standards for SBS Modified Bitumen Roof Assemblies

Back to SBS Modified Bitumen Construction Details

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.