Search results

Jump to: navigation, search

Search results

  • :#Only RoofStar-accepted insulation, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bitumino ...''Accepted Roof Insulation products'''] for '''RoofStar Guaranteed''' roof systems.
    18 KB (2,588 words) - 17:28, 13 March 2018
  • ...ntact with asphaltic membranes of any type shall be primed both sides with membrane manufacturers approved primer and embedded in a trowel coating of compatibl ...e corners shall be closed and soldered. <span class="principles">Use only membrane manufacturer’s approved proprietary urethane based structural sealants to
    14 KB (1,967 words) - 22:58, 9 November 2018
  • <div id="METALBASE-SBS"></div> ...rsion in water with the exception of protected and modified protected roof systems.
    10 KB (1,482 words) - 22:00, 7 March 2018
  • ==== [[Eave Protection & Underlayment (Architectural Metal Roofing)]] ==== ==== [[Flexible Membrane Roofing Systems: SBS|SBS Membranes]] ====
    2 KB (254 words) - 17:18, 6 June 2016
  • ==== [[Eave Protection & Underlayment (Architectural Metal Roofing)]] ==== ==== [[Flexible Membrane Roofing Systems: SBS|SBS Membranes]] ====
    2 KB (254 words) - 17:18, 6 June 2016
  • <div class="panel-heading">Welcome to the '''RCABC Roofing Practices Manual'''</div> The RPM Online is the official version of the Roofing Practices Manual and supersedes all other printed versions which may be in
    7 KB (990 words) - 20:54, 2 August 2016
  • <big><big><big><big><big>Standard for Grade-level Waterproofing Systems</big></big></big></big></big> ...spaces, subsequently this makes <b><i>waterproofing and protected roofing systems,</i></b> not dampproofing, the only reliable options to prevent the passage
    117 KB (13,071 words) - 18:36, 5 April 2024
  • <i>Product Group:</i> <b>SBS MODIFIED BITUMINOUS MEMBRANES</b> ...membranes, and the High Performance Composite systems, all tough, flexible SBS polymer modified bitumen prefabricated sheets, appropriately reinforced and
    14 KB (2,024 words) - 18:30, 9 November 2016
  • <i>Product Group:</i> <b>SBS MODIFIED BITUMINOUS MEMBRANES</b> ...roofing systems are the TORCHFLEX and MODIFLEX membranes: tough, flexible, SBS polymer modified bitumen prefabricated sheets, appropriately reinforced and
    11 KB (1,543 words) - 18:21, 9 November 2016
  • Product Group: <b>SBS MODIFIED BITUMINOUS WATERPROOFING MEMBRANES</b> ...roofing systems are the TORCHFLEX and MODIFLEX membranes: tough, flexible, SBS polymer modified bitumen prefabricated sheets, appropriately reinforced and
    8 KB (1,205 words) - 18:26, 9 November 2016
  • <i>Product Group:</i> <b>BUILT-UP ROOFING SYSTEMS EXPOSED MEMBRANES, INSULATED </b> ...S membranes, see the [[GAF SBS Membrane Installation Guidelines|'''GAF SBS Membrane Installation Guidelines''']] elsewhere in this Manual.
    25 KB (3,685 words) - 16:52, 4 November 2016
  • <i>Product Group:</i> <b>SBS MODIFIED PROPRIETARY BUR SYSTEM</b> ...land Company is a leading manufacturer and distributor of high-performance roofing and flooring solutions for commercial, industrial, and public properties. W
    22 KB (3,005 words) - 17:17, 4 November 2016
  • Product Group: <b>SBS MODIFIED BITUMINOUS WATERPROOFING MEMBRANES</b> ...membranes and the high performance composite systems, all tough, flexible SBS polymer modified bitumen prefabricated sheets, appropriately reinforced an
    7 KB (1,060 words) - 18:29, 9 November 2016
  • ...eaves, walls, vents, etc. must be sealed to prevent moisture from entering roofing or between plies of stripping. ...2 (1" in 12"), back-nail mopped sheet at 600 mm (2' 0") using large-headed roofing nails. On insulated roofs, install nailing strips to facilitate back-nailin
    14 KB (2,005 words) - 21:35, 25 January 2017
  • ...he roofing assembly, be it membrane, ballast or growing medium (soil). All membrane flashing (stripping) terminating on a vertical surface must be mechanically ...s tested to and compliant with [[RoofStar Guarantee Standards for SBS Roof Systems#SBS4| '''CSA A123.21''']] (latest edition), and include a calculation for t
    12 KB (1,724 words) - 21:46, 16 February 2018
  • ...ntact with asphaltic membranes of any type shall be primed both sides with membrane manufacturers approved primer and embedded in a trowel coating of compatibl ...e corners shall be closed and soldered. <span class="principles">Use only membrane manufacturer’s approved proprietary urethane based structural sealants to
    14 KB (1,966 words) - 15:51, 30 March 2017
  • ...rsion in water with the exception of protected and modified protected roof systems. ...tripping plies shall be two overlapping plies of a minimum 2 mm reinforced SBS modified bitumen base sheet or two overlapping plies of a minimum 180 g / m
    10 KB (1,568 words) - 22:02, 7 March 2018
  • :#Only RoofStar-accepted insulation, specifically listed by membrane manufacturers in the RPM as acceptable for use with their modified bitumino ...epted Roof Insulation products''']] for '''''RoofStar Guaranteed''''' roof systems.
    18 KB (2,573 words) - 17:29, 13 March 2018
  • ...is applied" (adapted from ''ASTM D1079-18 Standard Terminology Relating to Roofing and Waterproofing'')|| 2021-June-30 }}. ...to render the deck surface continuous or suitable for the installation of roofing materials|| 2021-June-30 }}.
    27 KB (3,843 words) - 16:12, 15 October 2021
  • :<big><big>'''Roof Waterproofing Systems'''</big></big> ...ials - SBS Modified Bitumen Membrane Systems|SBS Modified Bitumen Membrane Systems]]</big>
    2 KB (224 words) - 21:55, 3 September 2021

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)