<strong>FOR USE WHEN DISCONNECT OF CABLES OR PIPES IS IMPRACTICAL</strong> | <strong>FOR USE WHEN DISCONNECT OF CABLES OR PIPES IS IMPRACTICAL</strong> | ||
− | + | [[File:6.3.6.1.jpg|class=img-responsive]] | |
− | [[File:6.3.6.1.jpg]] | + | </div> |
− | + | </div><!-- COL-MD-6 --> | |
− | |||
+ | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
;1) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. | ;1) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. | ||
Line 21: | Line 26: | ||
;(B) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOWOODBLOCKING|'''Wood Blocking''']] | ;(B) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOWOODBLOCKING|'''Wood Blocking''']] | ||
;(C) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPO2PIECE|'''Metal 2-Piece Flashing''']]: Assembled around protrusion, laid over compatible sealant on top of primary membrane. Mechanically fasten two components together and fasten flange to wood blocking or deck. | ;(C) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPO2PIECE|'''Metal 2-Piece Flashing''']]: Assembled around protrusion, laid over compatible sealant on top of primary membrane. Mechanically fasten two components together and fasten flange to wood blocking or deck. | ||
− | + | </div><!-- COL-6-MD --> | |
+ | </div><!-- PANEL BODY --> | ||
+ | </div><!-- PANEL --> | ||
Revision as of 18:55, 19 August 2016
TPO/PVC Details
1 WORK INCLUDED
- 1) Gypsum Deck Overlay
- May be required depending on insulation thickness or when required as a thermal barrier by design authority.
- (2) Vapour Retarder
- If required by design authority.
- (3) Insulation
- Mechanically attached or loose laid for ballasted roof assemblies. Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
- (4) Single-ply Membrane
- Installed according to manufacturer’s instructions and RoofStar Guarantee Standards.
- (5) Mastic
- Compatible mastic or sealant.
- (6) Membrane Flashing
- Adhered to curb according to manufacturer's printed specifications using proprietary adhesive. Must be carried to outside of parapet or minimum 200 mm (8") above finished roof surface. Thermoplastic membrane may be welded or chemically bonded.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Wood Blocking
- (C) Metal 2-Piece Flashing
- Assembled around protrusion, laid over compatible sealant on top of primary membrane. Mechanically fasten two components together and fasten flange to wood blocking or deck.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.