Difference between revisions of "WP Details:F1.7.11 (Bi-Level Drain - Hard Surface: Low Pervious Wearing Course)"
Difference between revisions of "WP Details:F1.7.11 (Bi-Level Drain - Hard Surface: Low Pervious Wearing Course)"
(→WORK INCLUDED) |
|||
Line 12: | Line 12: | ||
(1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications. | (1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications. | ||
− | (2) <b> Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab shown), installed as per <i>RGC Guarantee Standards E </i>and Membrane Manufacturer's installation specifications. | + | (2) <b> Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab shown), installed as per {{hilite | <i>RGC Guarantee Standards E </i> || 2016-November-19 }} and Membrane Manufacturer's installation specifications. |
(3) <b>Protection Board & Filter Fabric</b>: Proprietary (purpose-made) drainage boards and filter fabric required with semi- impermeable sand and gravel beds designed to provide levelling for unit masonry. | (3) <b>Protection Board & Filter Fabric</b>: Proprietary (purpose-made) drainage boards and filter fabric required with semi- impermeable sand and gravel beds designed to provide levelling for unit masonry. | ||
− | |||
=== WORK BY OTHERS === | === WORK BY OTHERS === |
Revision as of 21:55, 19 August 2016
1 WORK INCLUDED
(1) Membrane Primer or Adhesive: proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
(2) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.
(3) Protection Board & Filter Fabric: Proprietary (purpose-made) drainage boards and filter fabric required with semi- impermeable sand and gravel beds designed to provide levelling for unit masonry.
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab shown
(B) Drain Body: Proprietary Bi-level cast iron roof for waterproofing assembly with low previous wearing courses.
(C) Drain inlet: Drainage opening at top surface of semi- impermeable wearing courses on Bi-Level drain. (D) Drainage Board /Filter Fabric: Proprietary drainage board approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.
(E) Sand/ Gravel Bed with Filter Mat: synthetic water permeable fabric required to contain sand beds for unit masonry (bricks, pavers and stone).
(F) Unit Masonry Wearing Course: Concrete brick, pavers and stone on sand or gravel beds designed to support predicted live loads.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to Waterproofing Application