WP Details:F1.7.11 (Bi-Level Drain - Hard Surface: Low Pervious Wearing Course)

Jump to: navigation, search

WP Details:F1.7.11 (Bi-Level Drain - Hard Surface: Low Pervious Wearing Course)

Revision as of 18:11, 12 October 2016 by James Klassen (talk | contribs)
RoofStar Guarantee Standards are blue-linked
Waterproofing Details for Plazas, Promenades and Terraces

9.6.11.jpg

1 WORK INCLUDED

(1) Membrane Primer or Adhesive: proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(2) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.

(3) Protection Board & Filter Fabric: Proprietary (purpose-made) drainage boards and filter fabric required with semi- impermeable sand and gravel beds designed to provide levelling for unit masonry.

2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab shown

(B) Drain Body: Proprietary Bi-level cast iron roof for waterproofing assembly with low previous wearing courses.

(C) Drain inlet: Drainage opening at top surface of semi- impermeable wearing courses on Bi-Level drain.

(D) Drainage Board /Filter Fabric: Proprietary drainage board approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with Section 14, Penetrations and Drains.

(E) Sand/Gravel Bed with Filter Mat: Synthetic water permeable fabric required to contain sand beds for unit masonry (bricks, pavers and stone).

(F) Unit Masonry Wearing Course: Concrete brick, pavers and stone on sand or gravel beds designed to support predicted live loads.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.