WP Details:F1.7.2 (Wearing Course - Unit Masonry)

Jump to: navigation, search

WP Details:F1.7.2 (Wearing Course - Unit Masonry)

Revision as of 17:25, 23 December 2015 by James Klassen (talk | contribs) (WORK BY OTHERS)

9.6.2.jpg


1 WORK INCLUDED

(1)Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.

(2)Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(3)Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.

(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).


2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab depicted.

(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.

(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RGC Guarantee Standards E. For RGC accepted Moisture Survey Tape System s - refer to Section 2.2.

NOTE
Refer to RGC Guarantee Standards E for additional requirements.


Back to Waterproofing Application

Back to Waterproofing Construction Details

Back to Construction Details