(1) <b>Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab depicted), installed as per [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']] and Membrane Manufacturer's installation specifications.  
+
(1) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab depicted), installed as per [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']] and Membrane Manufacturer's installation specifications.  
  
(2) <b> Membrane Flashing (stripping): </b>Carried up walls a minimum 200 mm (8") above membrane surface (Deck) and a minimum of 100mm (4") above top surface of permeable waterproofing wearing surfaces and overburdens.  
+
(2) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPSTRIPPING '''Membrane Flashing (stripping)''']: Carried up walls a minimum 200 mm (8") above membrane surface (Deck) and a minimum of 100mm (4") above top surface of permeable waterproofing wearing surfaces and overburdens.  
  
 
(3) <b> Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.
 
(3) <b> Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.
  
(4) <b>Metal Base Flashing:</b> Required on all waterproofing assemblies flashing lengths joined by use of S-locks or  standing seam joints.
+
(4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMETAL '''Metal Base Flashing''']: Required on all waterproofing assemblies flashing lengths joined by use of S-locks or  standing seam joints.
  
(5) <b>Metal Counter Flashing:</b> Set in reglet fastened with expanding type concrete pins, join flashing lengths by use of S-locks or standing seam joints.
+
(5) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMETAL '''Metal Counter Flashing''']: Set in reglet fastened with expanding type concrete pins, join flashing lengths by use of S-locks or standing seam joints.
  
 
(6) <b> Fasteners: </b>Suitable expanding type concrete pins.  
 
(6) <b> Fasteners: </b>Suitable expanding type concrete pins.  
Line 28: Line 28:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
(A)<b>Concrete Wall:</b> Must be dry, smooth and primed for membrane flashing to be adhered directly.  (Plywood or fibre-mat reinforced cement board may be required).
+
(A) <b>Concrete Wall:</b> Must be dry, smooth and primed for membrane flashing to be adhered directly.  (Plywood or fibre-mat reinforced cement board may be required).
  
(B)<b>Reglet: </b>minimum 75mm (3/4") in depth, saw cut or manufactured preformed reglet.
+
(B) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPREGLET '''Reglet''']: </b>minimum 75mm (3/4") in depth, saw cut or manufactured preformed reglet.
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->

Revision as of 17:52, 12 October 2016

RoofStar Guarantee Standards are blue-linked
Waterproofing Details for Plazas, Promenades and Terraces

9.6.9.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab depicted), installed as per RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.

(2) Membrane Flashing (stripping): Carried up walls a minimum 200 mm (8") above membrane surface (Deck) and a minimum of 100mm (4") above top surface of permeable waterproofing wearing surfaces and overburdens.

(3) Membrane Primer or Adhesive: proprietary primer or adhesive, application and quantities as directed by membrane manufacturers published application specifications.

(4) Metal Base Flashing: Required on all waterproofing assemblies flashing lengths joined by use of S-locks or standing seam joints.

(5) Metal Counter Flashing: Set in reglet fastened with expanding type concrete pins, join flashing lengths by use of S-locks or standing seam joints.

(6) Fasteners: Suitable expanding type concrete pins.

(7) Caulking: Polyurethane sealant, fill void and tool smooth.

2 RELATED WORK BY OTHERS

(A) Concrete Wall: Must be dry, smooth and primed for membrane flashing to be adhered directly. (Plywood or fibre-mat reinforced cement board may be required).

(B) Reglet: minimum 75mm (3/4") in depth, saw cut or manufactured preformed reglet.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.