Difference between revisions of "Materials:(M. Kirk) FF100 Snap Lock"

Jump to: navigation, search

Difference between revisions of "Materials:(M. Kirk) FF100 Snap Lock"

 
(One intermediate revision by the same user not shown)
Line 5: Line 5:
 
<big><big>Division C - Accepted Materials</big></big>
 
<big><big>Division C - Accepted Materials</big></big>
 
<hr>
 
<hr>
<big><big><big><big><big>SS675 Mechanical Lock</big></big></big></big></big><br>
+
<big><big><big><big><big>(MK) FF100 Snap Lock</big></big></big></big></big><br>
<big><big><big>by Mack Kirk Roofing & Sheet Metal Ltd.</big></big></big><br>
+
<big><big><big>by Mack Kirk Industries Ltd.</big></big></big><br>
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 15: Line 15:
 
|-
 
|-
 
|  
 
|  
;'''Manufacturer''': Mack Kirk Roofing & Sheet Metal Ltd.
+
;Manufacturer: Mack Kirk Roofing & Sheet Metal Ltd.
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
+
;Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
;'''Product Group - Standing Seam Metal Roof System'''
+
;Product Group: Standing Seam Metal Roof System
;'''Panel Machine''': New Tech Machinery, Model SSQ2 MultiPro Roof and Wall Panel Machine
+
;Panel Machine: New Tech Machinery (Model SSQ2 MultiPro Roof and Wall Panel Machine)
;'''Panel Name''': MK FF100 Snap Lock
+
;Accepted for the ''RoofStar Guarantee Program'': June 12, 2025
;'''Seam Type''': Snap Lock (Flange-fastened)
+
;Accepted for application in: Water-shedding Roof Systems
;'''Date of Acceptance''': June 12, 2025
+
;Panel Name: (MK) FF100 Snap Lock
 +
;Seam Type: Snap Lock (Flange-fastened), 25.4 mm (1")
  
 
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
 
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.

Latest revision as of 17:39, 26 June 2025



Division C - Accepted Materials


(MK) FF100 Snap Lock
by Mack Kirk Industries Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
Mack Kirk Roofing & Sheet Metal Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group
Standing Seam Metal Roof System
Panel Machine
New Tech Machinery (Model SSQ2 MultiPro Roof and Wall Panel Machine)
Accepted for the RoofStar Guarantee Program
June 12, 2025
Accepted for application in
Water-shedding Roof Systems
Panel Name
(MK) FF100 Snap Lock
Seam Type
Snap Lock (Flange-fastened), 25.4 mm (1")

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The New Tech SSQ2 is an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 610 mm (24") wide; stiffening ribs are standard.

On-site roll forming provides for the elimination of end laps with continuous panel forming capabilities. Note that the maximum length of this panel is restricted in the "RGC Standard for Architectural Sheet Metal (ASM) Roofs" to 10 m (30') because of the coefficient of expansion (Ref. Article 9.2.1.1., Sentence (8)). This panel is also suitable for application only on a solid substrate (uninsulated roofs).

SYSTEM DESCRIPTION

  1. General: The MK FF100 Snap Lock is a flange-fastened, concealed fastener roofing panel, secured with screws through a flange along one side of the panel. The panel can be formed in any width between 300 mm (12") to 610 mm (24"). The male leg locks along the entire length of the panel and does not rely upon clips to provide additional locking.
  2. Range of application: on wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction.
  3. Fabrication:
    1. Unless otherwise shown on drawings or specified herein, fabricate panels in continuous one piece lengths and fabricate flashings and accessories in longest practical lengths.
    2. Roofing panels shall be factory formed or site formed.
    3. Verify prior to fabrication.
    4. If field measurements differ from drawing dimensions, notify Architect / Professional Engineer prior to fabrication.
  4. Fasteners (Screws): Fasteners used to secure the panel to the deck to be determined by engineering requirements.
  5. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

MK FF100 Snap Lock Panel
MK FF100 Snap Lock (Profile).jpg

TECHNICAL DATA SHEET

Click below for the Technical Data Sheet

Technical Data Sheet

SITE CONDITIONS

  1. Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home