Difference between revisions of "Working Page 9"

Jump to: navigation, search

Difference between revisions of "Working Page 9"

(Blanked the page)
(Tag: Blanking)
 
 
(3 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
  
 +
<big><big>Division D - Construction Details</big></big>
 +
<hr>
 +
<big><big><big><big><big>TPO | Expansion Joint (Field) ([[TPO_Roof_Systems_Standard#10.3.6.1._Expansion_Joints |Article 10.3.6.1.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
 +
<div class="panel panel-info">
 +
<div class="panel-heading"><big>'''TPO Details'''</big></div>
 +
<div class="panel-body">
 +
<div class="col-md-7">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:Part 10 - CD - Expansion Joints (Field) TPO.png |link=https://rpm.rcabc.org/images/a/ad/Part_10_-_CD_-_Expansion_Joints_%28Field%29_TPO.png | class=img-responsive]]
 +
</div>
 +
</div><!-- COL-MD-7 -->
 +
 +
<div class="col-md-5">
 +
=== WORK INCLUDED ===
 +
;(1) [[EPDM Roof Systems Standard#PART_10|'''Roof membrane''']]: Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with.
 +
;(2) [[EPDM Roof Systems Standard#PART_10|'''Expansion joint (elastomeric product illustrated)''']]: This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others.  Secured to substrate as required by manufacturer.
 +
;(3) '''Reinforced membrane strip''': Applied to cover the control joint and seal it to the membrane system.
 +
;(4) [[EPDM Roof Systems Standard#PART_13|'''Metal cap (coping) flashing''']]: Fabricated and installed as required in Part 13.
 +
;(5) [[EPDM Roof Systems Standard#PART_13|'''Metal counter-flashing''']]: The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movement.  Dimensions are project-specific.
 +
 +
 +
<hr>
 +
 +
=== RELATED WORK BY OTHERS ===
 +
;(A) [[TPO Roof Systems Standard#PART_2|'''Acceptable deck''']]
 +
;(B) '''Expansion joint structure'''
 +
</div><!-- COL-5-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
 +
 +
'''NOTE''': See the [[TPO Roof Systems Standard | '''Standard''']] for additional requirements.
 +
 +
<hr>
 +
 +
[[TPO Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''TPO Roof System Details'']]
 +
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
 +
 +
{{Template:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 15:33, 30 October 2026


Division D - Construction Details


TPO | Expansion Joint (Field) (Article 10.3.6.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

TPO Details

Part 10 - CD - Expansion Joints (Field) TPO.png

1 WORK INCLUDED

(1) Roof membrane
Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with.
(2) Expansion joint (elastomeric product illustrated)
This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others. Secured to substrate as required by manufacturer.
(3) Reinforced membrane strip
Applied to cover the control joint and seal it to the membrane system.
(4) Metal cap (coping) flashing
Fabricated and installed as required in Part 13.
(5) Metal counter-flashing
The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movement. Dimensions are project-specific.



2 RELATED WORK BY OTHERS

(A) Acceptable deck
(B) Expansion joint structure

NOTE: See the Standard for additional requirements.


Back to TPO Roof System Details

Home

© RCABC 2026
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.