<big><big><big><big><big>SBS | Low Door Opening ([[SBS_Roof_Systems_Standard#10.3.4.5._Doors.2C_Windows.2C_and_Wall_Openings | Article 10.3.4.5.]])</big></big></big></big></big>
 
<big><big><big><big><big>SBS | Low Door Opening ([[SBS_Roof_Systems_Standard#10.3.4.5._Doors.2C_Windows.2C_and_Wall_Openings | Article 10.3.4.5.]])</big></big></big></big></big>
 
{{Template:Construction Details Header}}
 
{{Template:Construction Details Header}}
<div class="panel panel-success">
+
<div class="panel panel-info">
 
<div class="panel-heading"><big>'''SBS Details'''</big></div>
 
<div class="panel-heading"><big>'''SBS Details'''</big></div>
 
<div class="panel-body">
 
<div class="panel-body">
 
<div class="col-md-6">
 
<div class="col-md-6">
 +
<br>
 
<div style="text-align:center; vertical-align:center">
 
<div style="text-align:center; vertical-align:center">
[[File:SBS Low Door Opening.jpg|link=https://rpm.rcabc.org/images/2/26/SBS_Low_Door_Opening.jpg |class=img-responsive]]
+
[[File:Part 10 - Construction Detail - Low Door Opening - SBS.png|link=https://rpm.rcabc.org/images/6/62/Part_10_-_Construction_Detail_-_Low_Door_Opening_-_SBS.png |class=img-responsive]]
 
</div>
 
</div>
 
</div><!-- COL-MD-6 -->
 
</div><!-- COL-MD-6 -->
Line 20: Line 21:
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
 
;(1) [[SBS Roof Systems Standard#PART_1|'''Roof system''']]: Conventionally insulated system shown (refer to the membrane Standard for requirements).
 
;(1) [[SBS Roof Systems Standard#PART_1|'''Roof system''']]: Conventionally insulated system shown (refer to the membrane Standard for requirements).
;(2) [[SBS Roof Systems Standard#PART_9|'''Field membrane''']]: SBS-modified bituminous system shown (see Part 9 for standards)
+
;(2) [[SBS Roof Systems Standard#PART_9|'''Field membrane''']]: SBS-modified bituminous system shown (see Part 9 for requirements)
 
;(3) [[SBS Roof Systems Standard#PART_10|'''Self-adhered membrane (pre-flashing)''']]: Apply over rough sill or sill woodwork.  Prime as required.
 
;(3) [[SBS Roof Systems Standard#PART_10|'''Self-adhered membrane (pre-flashing)''']]: Apply over rough sill or sill woodwork.  Prime as required.
 
;(4) [[SBS Roof Systems Standard#PART_10|'''Metal water-stop flashing''']]: Dimensions as specified in design.  Mechanically attach to inside face of door sill.  Cut flashing to fit opening width.
 
;(4) [[SBS Roof Systems Standard#PART_10|'''Metal water-stop flashing''']]: Dimensions as specified in design.  Mechanically attach to inside face of door sill.  Cut flashing to fit opening width.
Line 28: Line 29:
 
;(8) [[SBS Roof Systems Standard#PART_10|'''Membrane flashing''']]: Applicable for exterior-insulated walls.  Seals roof membrane flashing to air/vapour barrier on wall and provides sufficient exposure for positive union with WRB (by others).  Mechanically secure membrane (metal base flashing used for securement in this detail).
 
;(8) [[SBS Roof Systems Standard#PART_10|'''Membrane flashing''']]: Applicable for exterior-insulated walls.  Seals roof membrane flashing to air/vapour barrier on wall and provides sufficient exposure for positive union with WRB (by others).  Mechanically secure membrane (metal base flashing used for securement in this detail).
 
;(9) [[SBS Roof Systems Standard#PART_10|'''Metal base flashing (walls)''']]: Optional; protects membrane flashing from damage, and functions as removable panel to permit access to membrane flashing for future replacement.
 
;(9) [[SBS Roof Systems Standard#PART_10|'''Metal base flashing (walls)''']]: Optional; protects membrane flashing from damage, and functions as removable panel to permit access to membrane flashing for future replacement.
;(10) [[SBS Roof Systems Standard#PLATFORM|'''Pavers and pedestals''']]: May be installed by others, if specified.  See '''Part 14''' for material and application requirements.  Must be at least 12 mm (1/2”) away from other pavers, and from membrane flashing or metal base flashing, to permit adequate drainage.
+
;(10) [[SBS Roof Systems Standard#PART_14|'''Pavers and pedestals''']]: May be installed by others, if specified.  See '''Part 14''' for material and application requirements.  Must be at least 12 mm (1/2”) away from other pavers, and from membrane flashing or metal base flashing, to permit adequate drainage.
  
 
<hr>
 
<hr>
Line 34: Line 35:
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
 
;(A) '''Wall and cladding''': Generic and representative only.
 
;(A) '''Wall and cladding''': Generic and representative only.
;(B) '''WRB (Water Resistant Barrier)''': Generic and representative only.
+
;(B) '''WRB (Water Resistive Barrier)''': Generic and representative only.
 
;(C) '''Door and jamb assembly''': Generic and representative only.
 
;(C) '''Door and jamb assembly''': Generic and representative only.
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
Line 46: Line 47:
 
[[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''"SBS" Roof System Details'']]
 
[[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''"SBS" Roof System Details'']]
  
[[Main Page | <i class="fa fa-home fa"></i> Home]]
+
[[RCABC Roofing Practices Manual| <i class="fa fa-home fa"></i> Home]]
  
{{Tempate:RPM Page Footer with Copyright and Current Date}}
+
{{Template:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 16:23, 7 November 2025



Division D - Construction Details


SBS | Low Door Opening ( Article 10.3.4.5.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details


Part 10 - Construction Detail - Low Door Opening - SBS.png

1 WORK INCLUDED

(1) Roof system
Conventionally insulated system shown (refer to the membrane Standard for requirements).
(2) Field membrane
SBS-modified bituminous system shown (see Part 9 for requirements)
(3) Self-adhered membrane (pre-flashing)
Apply over rough sill or sill woodwork. Prime as required.
(4) Metal water-stop flashing
Dimensions as specified in design. Mechanically attach to inside face of door sill. Cut flashing to fit opening width.
(5) Membrane flashing
Base membrane shown. Install to overlap and seal in metal water-stop flashing.
(6) Membrane gussets
Install in corners to seal joints.
(7) Metal base flashing (under door)
Optional; protection for membrane when pavers are installed (shown), or when exposed membrane is vulnerable to damage. Mechanical fasteners must be at least 87.5 mm (3-1/2”) above the drainage plane.
(8) Membrane flashing
Applicable for exterior-insulated walls. Seals roof membrane flashing to air/vapour barrier on wall and provides sufficient exposure for positive union with WRB (by others). Mechanically secure membrane (metal base flashing used for securement in this detail).
(9) Metal base flashing (walls)
Optional; protects membrane flashing from damage, and functions as removable panel to permit access to membrane flashing for future replacement.
(10) Pavers and pedestals
May be installed by others, if specified. See Part 14 for material and application requirements. Must be at least 12 mm (1/2”) away from other pavers, and from membrane flashing or metal base flashing, to permit adequate drainage.

2 RELATED WORK BY OTHERS

(A) Wall and cladding
Generic and representative only.
(B) WRB (Water Resistive Barrier)
Generic and representative only.
(C) Door and jamb assembly
Generic and representative only.

NOTE: See the Standard for additional requirements.