Difference between revisions of "Accepted Materials - Grade-level Waterproofing"
Difference between revisions of "Accepted Materials - Grade-level Waterproofing"
(→Membranes) |
(→Membrane Systems) |
||
Line 16: | Line 16: | ||
===[http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE Membrane Systems]=== | ===[http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE Membrane Systems]=== | ||
:RGC specifically accepted waterproofing membrane systems listed in the Accepted Materials of this Manual include the following: | :RGC specifically accepted waterproofing membrane systems listed in the Accepted Materials of this Manual include the following: | ||
− | :* Two Ply SBS Modified Bituminous | + | :* Two Ply SBS Modified Bituminous Membrane Systems |
− | :* Butyl Elastomeric Single Ply | + | :* Butyl Elastomeric Single Ply Membrane Systems ('''NOTE''': Currently, there are no butyl membranes accepted for use in the '''''RoofStar Guarantee Program''''') |
− | :* Poly Vinyl Chloride (PVC) Plastomeric Single Ply | + | :* Poly Vinyl Chloride (PVC) Plastomeric Single Ply Membrane Systems |
:* Hot Fluid - Applied, Rubberized Asphalt Systems. | :* Hot Fluid - Applied, Rubberized Asphalt Systems. | ||
Line 30: | Line 30: | ||
</div> | </div> | ||
<div class="toccolours mw-collapsible mw-collapsed"> | <div class="toccolours mw-collapsible mw-collapsed"> | ||
− | :<big><big>Thermoset | + | :<big><big>Thermoset (PVC) Membrane Systems</big></big> |
<div class="mw-collapsible-content">{{Template:Materials - Waterproofing Membranes (PVC)}}</div> | <div class="mw-collapsible-content">{{Template:Materials - Waterproofing Membranes (PVC)}}</div> | ||
</div> | </div> |
Revision as of 15:31, 10 November 2016
To view materials in any section listed below, click on the EXPAND button located at the right hand side of this page |
1 Vapour Retarders
- The RCABC does not specify Vapour Retarders, as they are not included in the RoofStar Guarantee Program. See manufacturer specifications where Vapour Retarders are required, and refer to proprietary products and installation instructions. This cross-reference is listed for information only.
2 Deck Overlay Boards
- Two layers of gypsum board shall be installed over steel decks as an acceptable substrate for adhered waterproofing membranes when cast in place concrete topping is not present. The first layer of gypsum or cement board shall be either be fully mechanically fastened to the deck or adhered to the deck with manufacturer's approved compatible polyurethane adhesive. The second board layer must be adhered with a compatible manufacturer's approved polyurethane adhesive.
- See the list below for materials acceptable for application on steel decks when specifying a RoofStar Waterproofing Guarantee:
Manufacturer | Product Name | Product Type | Thickness mm (in.) |
Weight (lb/square foot) |
Comp. Strength (psi, nominal) |
Acceptable Application |
---|---|---|---|---|---|---|
Plywood | Plywood overlay | 12.7 (1/2) min. | Variable | - | All decks* | |
Georgia-Pacific Canada Ltd. | DensDeck Roofboard | Moisture-resistant gypsum core board | 6.4 (1/4) | 1.100 | 500-900 | All decks |
Georgia-Pacific Canada Ltd. | DensDeck Roofboard | Moisture-resistant gypsum core board | 12.7 (1/2) | 1.950 | 500-900 | All decks |
Georgia-Pacific Canada Ltd. | DensDeck Roofboard | Moisture-resistant gypsum core board | 15.9 (5/8) | 2.500 | 500-900 | All decks |
Georgia-Pacific Canada Ltd. | DensDeck® Prime with EONIC Roof Board | Moisture-resistant gypsum core board | 6.4 (1/4) | 1.150 | 900 | All decks |
Georgia-Pacific Canada Ltd. | DensDeck® Prime with EONIC Roof Board | Moisture-resistant gypsum core board | 12.7 (1/2) | 1.975 | 900 | All decks |
Georgia-Pacific Canada Ltd. | DensDeck® Prime with EONIC Roof Board | Moisture-resistant gypsum core board | 15.9 (5/8) | 2.550 | 900 | All decks |
USG (CGC) SecureRock | Securerock Gypsum Fibre Roof Board | Moisture-resistant gypsum core board | 6.4 (1/4) | 1.570 | 1800 | All decks |
USG (CGC) SecureRock | Securerock Gypsum Fibre Roof Board | Moisture-resistant gypsum core board | 9.5 (3/8) | 1.960 | 1800 | All decks |
USG (CGC) SecureRock | Securerock Gypsum Fibre Roof Board | Moisture-resistant gypsum core board | 12.7 (1/2) | 2.760 | 1800 | All decks |
USG (CGC) SecureRock | Securerock Gypsum Fibre Roof Board | Moisture-resistant gypsum core board | 15.9 (5/8) | 3.200 | 1800 | All decks |
USG (CGC) SecureRock | Securerock Glass-Mat Roof Board | Moisture-resistant gypsum core board | 6.4 (1/4) | 1.200 | 700-1000 | All decks |
USG (CGC) SecureRock | Securerock Glass-Mat Roof Board | Moisture-resistant gypsum core board | 12.7 (1/2) | 2.000 | 700-1000 | All decks |
USG (CGC) SecureRock | Securerock Glass-Mat Roof Board | Moisture-resistant gypsum core board | 15.9 (5/8) | 2.700 | 700-1000 | All decks |
3 Membrane Systems
- RGC specifically accepted waterproofing membrane systems listed in the Accepted Materials of this Manual include the following:
- Two Ply SBS Modified Bituminous Membrane Systems
- Butyl Elastomeric Single Ply Membrane Systems (NOTE: Currently, there are no butyl membranes accepted for use in the RoofStar Guarantee Program)
- Poly Vinyl Chloride (PVC) Plastomeric Single Ply Membrane Systems
- Hot Fluid - Applied, Rubberized Asphalt Systems.
- Only waterproofing membrane systems that are fully adhered and have an accepted protection layer installed above the membrane (protected) qualifies for coverage under the RoofStar Guarantee Program.
- All waterproofing system accessory components must be supplied or be accepted for use by the membrane manufacturer.
- Modified Bituminous (SBS) Membrane Systems
- SBS (Styrene Butadiene Styrene) Modified Bituminous sheet waterproofing is prefabricated elastomeric membranes that are reinforced with mats consisting of polyester, fibreglass or a combination of both reinforcement types. SBS modified bituminous membranes are available in varied thicknesses with specific physical properties to satisfy the demands of particual waterproofing conditions as well as surface finishes that facilitate various application methods.
- Composition
- Bituminous and modified bituminous flexible membrane systems are composite sheet membranes which are thermoplastic in nature but display variable elastomeric properties when modified. These sheets generally consist of bitumen (oxidized or modified), reinforcement, and surfacing materials. The performance of these membranes may be compromised by subtle, seemingly inconsequential changes in composition.
- The formulation of the bitumen is critical, particularly when its physical properties are modified by the addition of polymers. Bitumen is most commonly modified with styrene butadiene styrene (SBS). The manufacturer must ensure that a suitable degree of compatibility exists between the bitumen and the polymer and that a thorough mix has been obtained. The careful selection and combination of bitumen and polymer (the type of modifier, the percentage of polymer used, etc.) determines the physical properties and long term performance of the modified bituminous "binder". The binder provides the membrane with its waterproofing capability and may impart the following properties:
- low temperature flexibility
- elasticity
- high temperature resistance to flow
- resistance to aging
- The bitumen utilized for oxidized bituminous membranes has been "blown", similar to roofing asphalt. This produces a higher softening point and, therefore, a more useful temperature range.
- The physical properties of the binder are further enhanced by the imposition by saturation or coating onto a carrier or reinforcing mat, most commonly a textile such as:
- non-woven spun-bonded polyester
- woven polyester scrim
- fibreglass mats
- woven fibreglass cloth
- combinations of the above.
- 1. Base Membranes
- 2. Cap Membranes
- 3. Self-adhering Membranes
Manufacturer | Product Name | Nominal Product Thickness (mm) | Approximate Weight (Kg/m2) | Reinforcement Material | Reinforcement Material Weight (g/m2) | Applicator Training |
---|---|---|---|---|---|---|
Soprema Inc. | Sopralene Flam Stick | ‒ | ‒ | ‒ | ‒ | ‒ |
- Thermoset (PVC) Membrane Systems
- Thermoplastic materials are defined as polymers which soften when heated and harden when cooled. This process is repetitive provided the material is not heated above the point at which decomposition occurs. No cross-linking or vulcanization occurs. In addition to heat welding, some materials can be solvent welded. These welds develop bonding strengths equalling or surpassing the strength of the base materials. Thermoplastic membrane systems that comply RGC Guarantee Standards, are installed as fully adhered protected waterproofing assembly, qualify for coverage under the RoofStar Guarantee Program.
- Composition
- Thermoplastic materials used for waterproofing decks on plazas, promenades and terraces in the RoofStar Guarantee Program include only PVC (Polyvinyl Chloride) Membranes:
- PVC is a thermoplastic material produced through the polymerization of vinyl chloride, resulting in a relatively hard, resinous material. This material is then formulated with compounds, such as plasticizers and stabilizers, depending on the physical properties required for end use. PVC formulations have been developed to suit numerous commercial and industrial applications.
- PVC waterproofing systems are single-ply membranes reinforced with polyester fabric or glass fibres, and in thicknesses usually ranging from 1.2 mm to 2.0 mm, depending on the manufacturer. The membrane is fully adhered and Seams are heat or chemically welded (see manufacturer's requirements).
- PVC membrane should conform to CGSB 37-GP-54M 1979, "Roofing and Waterproofing Membrane, Sheet Applied, Flexible, Polyvinyl Chloride" which lists two types of membrane, according to manufacture:
- Type 2 - reinforced
- and four classes, according to end use::* Class A - non-exposed roofing
- Class B - exposed roofing
- Class C - waterproofing
- Class D - flashing membrane asphalt compatible
- This standard covers requirements such as "thickness, lap joint strength, permeability, tensile strength, elongation at break, low temperature flexibility, water absorption, resistance to accelerated weathering, dimensional change after stress relaxation, and cone penetration"
- PVC membranes should be applied in conformance with CGSB 37-GP-55M 1979, "Application of Sheet Applied Flexible Polyvinyl Chloride Roof Membrane" and the membrane manufacturer's printed instructions.
Manufacturer | Product Name | Nominal Product Thickness (mm) | Approximate Weight (Kg/m2) | Reinforcement Material | Reinforcement Material Weight (g/m2) | Applicator Training |
---|---|---|---|---|---|---|
Sika Canada Inc. (Sarnafil) | Sarnafil G476 12 | ‒ | ‒ | ‒ | ‒ | ‒ |
Sika Canada Inc. (Sarnafil) | Sarnafil G476 15 | ‒ | ‒ | ‒ | ‒ | ‒ |
Sika Canada Inc. (Sarnafil) | Sarnafil G476 18 | ‒ | ‒ | ‒ | ‒ | ‒ |
Sika Canada Inc. (Sarnafil) | Sarnafil G476 20 | ‒ | ‒ | ‒ | ‒ | ‒ |
- Hot Fluid-Applied, Rubberized Asphalt Membrane Systems
- These are fully adhered waterproofing system that utilize hot applied rubberized asphalt compounds, with reinforcement scrims, to form monolithic (seamless) flexible waterproofing membranes.
- Composition
- Single component rubberized asphalt compound installed with reinforcement between two a two layer system. Hot applied rubberized asphalt is fully- adhered to both vertical and horizontal structural surfaces to form monolithic (seamless) flexible waterproofing membrane. Reinforced membrane flashings are installed in Hot applied rubberized asphalt at all deck transitions (wall to deck etc.).
- Hot applied rubberized asphalt systems are used for waterproofing on the following applications:
- Waterproofing in an Inverted Assembly
- Split Slab Construction for Plaza Decks
- Terraces, Prominades & Planters
Manufacturer | Product Name | Nominal Product Thickness, Wet (mm) | Approximate Weight (Kg/m2) | Reinforcement Material | Reinforcement Material Weight (g/m2) | Applicator Training |
---|---|---|---|---|---|---|
Carlisle Syntec Systems Canada | CCW 500R Liquid Applied Hot Rubberized Asphalt | 5.25 | 14 | Not stated | Not stated | Consult manufacturer |
Garland Canada Inc. | GMX Hot Applied Waterproofing | Awaiting TDS | Awaiting TDS | Awaiting TDS | Awaiting TDS | Consult manufacturer |
Henry Company Canada | 790-11 Hot Rubberized Asphalt | 5.5 | ‒ | Not stated | Not stated | Consult manufacturer |
Hydrotech Membrane Corporation | Monolithic Membrane 6125 | 5.5 | Not stated | ‒ | ‒ | Consult manufacturer |
Soprema Inc. | Colphene H | 5.5 | 7.2 | ‒ | ‒ | Consult manufacturer |
4 Membrane Protection Boards
- A RoofStar-accepted membrane protection layer (asphalt core board, cap sheet or protection mat), must be installed by the waterproofing contractor, and be compatible with waterproofing membrane. The protection layer shall be installed and secured, as soon as possible, upon completion of waterproofing membrane installation. Construction traffic, by other than waterproofing trade and membrane moisture monitor technicians, is not permitted until the membrane protection layer is completely installed and secured.
5 Insulation
- Extruded expanded polystyrene (Type 4), conforming to CAN/ULC-S701 (latest edition) with a compressive strength of 240 kPa (35psi) is the only commercially produced insulation suitable for use over waterproofing and protected membrane roofing systems. Extruded expanded polystyrene is available in a 600mm x 1200mm (2'x4') board size, has an aged R value of 5.0 per inch (RSI 0.87) and ranges in thickness' from 25mm (1") to 100mm (4").
Manufacturer | Product Name | System Test Type (Wind) | Density (kg/cu. m) | Compressive Strength (kPa) |
Compressive Strength (psi) |
Thermal Resistance (RSI/25.4 mm) |
Thermal Resistance (R/inch) |
---|---|---|---|---|---|---|---|
Dupont Specialty Products Division - Safety and Construction | Deckmate (Type 2) | ‒ | ‒ | 110 | 16 | 0.87 | 5 |
Dupont Specialty Products Division - Safety and Construction | Deckmate Plus (Type 3) | ‒ | ‒ | 140 | 20 | 0.87 | 5 |
Dupont Specialty Products Division - Safety and Construction | Roofmate (Type 4) | ‒ | ‒ | 240 | 35 | 0.87 | 5 |
Dupont Specialty Products Division - Safety and Construction | Roofmate CT (Type 4) | ‒ | ‒ | 240* | 35* | 0.87 | 5 |
Owens Corning Canada | Foamular C200 (Type 3) | ‒ | ‒ | 140 | 20 | 0.88 | 5 |
Owens Corning Canada | Foamular F350 (Type 4) | ‒ | ‒ | 240 | 35 | 0.88 | 5 |
Owens Corning Canada | Foamular 400 (Type 4) | ‒ | ‒ | 275 | 40 | 0.88 | 5 |
Owens Corning Canada | Foamular 600 (Type 4) | ‒ | ‒ | 415 | 60 | 0.88 | 5 |
Owens Corning Canada | Foamular 1000 (Type 4) | ‒ | ‒ | 690 | 100 | 0.88 | 5 |
Owens Corning Canada | Foamular 404 (Type 4) | ‒ | ‒ | 276 | 40 | 0.88 | 5 |
Owens Corning Canada | Foamular 604 (Type 4) | ‒ | ‒ | 414 | 60 | 0.88 | 5 |
Owens Corning Canada | Foamular 404RB (Type 4) | ‒ | ‒ | 276 | 40 | 0.84 | 4.75 |
Owens Corning Canada | Foamular 604RB (Type 4) | ‒ | ‒ | 414 | 60 | 0.84 | 4.75 |
Soprema Inc. | Sopra-XPS 35 | ‒ | ‒ | 350 | 51 | 0.88 | 5 |
Soprema Inc. | Sopra-XPS 40, 60, 100 | ‒ | ‒ | 500, 600, 700 | 73, 87, 102 | 0.88 | 5 |
6 Membrane Moisture Surveys & Monitoring Sensor Grids
- A membrane moisture scan survey and report that confirms the water tight integrity of waterproofing systems is a mandatory requirement of the RoofStar Guarantee Program for all waterproofing systems, prior to installation of overburdens or wearing courses. Membrane moisture survey scans must be performed by an independent moisture detection company, whose moisture detection system has been reviewed by the RCABC Technical Committee and deemed to be suitable for inclusion in the RoofStar Guarantee Program (Waterproofing). In addition, moisture monitoring sensor grids (conductance scanning grid) are mandatory and shall be installed on the top surface of all waterproofing membrane systems designed with inaccessible overburdens and wearing courses. The exceptions that do not require moisture monitoring sensor grids are pavers on pedestals and gravel ballast to a maximum 100mm (4") thick . Moisture monitoring sensor grids shall be installed prior to installation of overburdens or wearing courses and may be placed over protection boards or SBS membranes that have been set in hot fluid-applied modified asphalt.
- Note:
- Flood Testing is not a recommended practice but is at the discretion of the design authority or owner. If flood testing is required to water test waterproofing membranes, testing shall be conducted prior to installation of insulation and overburdens and be performed to ASTM D5957 - 98.
Manufacturer | Product & Service | Recognized Applications |
---|---|---|
Detec Systems Ltd. | Integrity Scans, Static and Monitored Electronic Leak Detection systems | PMR, MPMR, Waterproofing (Grade-level) |
International Leak Detection (ILD) | Integrity Scans, Static and Monitored Electronic Leak Detection systems | PMR, MPMR, Waterproofing (Grade-level) |
SMT: Structure Monitoring Technology | Integrity Scans, Static and Monitored Electronic Leak Detection systems | PMR, MPMR, Waterproofing (Grade-level) |
7 Accessories
An Accessory is a material that joins Primary or Secondary Materials together, or is connected to/with a Primary or Secondary material, but does not by its nature (apart from its installation) directly affect the waterproofing or water-shedding capabilities of the system.
Accessories are not currently part of the Accepted Material program, but are listed here for reference to specifiers, designers and installers. |
These membranes are not Accepted for use in the primary waterproofing system, but may be use as for an ancillary function - for example, as protective membranes (a 'sacrificial' cap membrane).
Manufacturer | Product Name | Description | Application Method | Suitability |
---|---|---|---|---|
Polyglass USA, Inc. | Polyfresko G SA | APP membrane | Self-adhering | Walkways, accessory surfaces |
Polyglass USA, Inc. | Polyfresko G FR | APP membrane (fire resistant) | Heat-welding | Walkways, accessory surfaces |
Polyglass USA, Inc. | Polyfresko G | APP membrane | Heat-welding, hot asphalt, cold processing | Walkways, accessory surfaces |
Polyglass USA, Inc. | Polyflex G FR | APP membrane (fire resistant) | Heat-welding | Walkways, accessory surfaces |
Polyglass USA, Inc. | Polyflex G HP | APP membrane | Heat-welding, hot asphalt, cold processing | Walkways, accessory surfaces |
Coatings are not a waterproofing product, but rather enhance solar reflectivity or other properties of a membrane. The inclusion of these materials, although acceptable under the RoofStar Guarantee Program, is not part of the Guarantee.
Manufacturer | Product Name | Description | Application | Applicator Training |
---|---|---|---|---|
Soprema Inc. | R-Nova Plus | polyurethane/acrylic-based waterproofing liquid membrane/coating | See Product Details | Consult Manufacturer |
Soprema Inc. | R-Nova Plus Mastic | polyurethane/acrylic-based waterproofing liquid mastic | See Product Details | Consult Manufacturer |
Soprema Inc. | R-Nova Plus Matrix | polyurethane/acrylic-based waterproofing liquid paste | See Product Details | Consult Manufacturer |
Manufacturer | Product Name | Type | Size |
---|---|---|---|
Soprema Inc. | Soprajoint Plus 20 | expansion joint for low-slope membrane systems | ‒ |
Soprema Inc. | Soprajoint Plus 40 | expansion joint for low-slope membrane systems | ‒ |
Soprema Inc. | Soprajoint Plus 75 | expansion joint for low-slope membrane systems | ‒ |
Soprema Inc. | Soprajoint Plus 125 | expansion joint for low-slope membrane systems | ‒ |