Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

Jump to: navigation, search

Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

Line 1: Line 1:
 
{{Template:RPM Info}}
 
{{Template:RPM Info}}
 
+
<hr>
 
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
 
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
 
| colspan="2"  | <big>'''''Notice to Reader'''''</big>
 
| colspan="2"  | <big>'''''Notice to Reader'''''</big>
 
|-
 
|-
| style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and <u>not intended in their representation of an assembly to be prescriptive</u>.  Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the Standards, Guiding Principles and Recommendations of the '''RoofStar Guarantee Standards''' for a Waterproofing or Water-shedding System. Actual design with respect to dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of applicable '''''RoofStar Guarantee Standards''''' may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
+
| style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive.  Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[ASM Roof Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
 
|}
 
|}
 +
  
 
<div class="panel panel-success">
 
<div class="panel panel-success">
Line 26: Line 27:
 
;(1) Metal flashing underlayment/separation membrane: required for metal flashings installed on wood substrates.  
 
;(1) Metal flashing underlayment/separation membrane: required for metal flashings installed on wood substrates.  
 
;(2) '''Metal edge flashing''': Installed to manufacturer's printed instructions.
 
;(2) '''Metal edge flashing''': Installed to manufacturer's printed instructions.
;(3) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMICE|'''Ice and water protection''']]: One ply of accepted self-adhered modified bituminous membrane.
+
;(3) [[ASM Roof Systems Standard#ASMICE|'''Ice and water protection''']]: One ply of accepted self-adhered modified bituminous membrane.
 
:* This application is required only for slopes less than 1:3 (4" in 12").  For slopes 1:3 or greater, see Construction Detail '''ASM 8.1.1 Eave Protection and Underlayment'''.
 
:* This application is required only for slopes less than 1:3 (4" in 12").  For slopes 1:3 or greater, see Construction Detail '''ASM 8.1.1 Eave Protection and Underlayment'''.
 
:* Slip sheet not shown for clarity
 
:* Slip sheet not shown for clarity
Line 33: Line 34:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable deck''']]
+
;(A) [[ASM Roof Systems Standard#ASMDECK|'''Acceptable deck''']]
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL -->
 
</div><!-- PANEL -->
  
 +
'''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements.
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
<hr>
  
<hr>
+
[[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']]
  
[[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems|<i class="fa fa-chevron-circle-right fa" ></i> RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems]]
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Revision as of 14:14, 31 August 2021


Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks


ASM Details

ASM 8.1.2 Self-Adhered Underlayment.jpg

Click below for a printable version of this page (N/A)
Print Sheet

1 WORK INCLUDED

(1) Metal flashing underlayment/separation membrane
required for metal flashings installed on wood substrates.
(2) Metal edge flashing
Installed to manufacturer's printed instructions.
(3) Ice and water protection
One ply of accepted self-adhered modified bituminous membrane.
  • This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Construction Detail ASM 8.1.1 Eave Protection and Underlayment.
  • Slip sheet not shown for clarity

2 RELATED WORK BY OTHERS

(A) Acceptable deck

NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.