Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

Jump to: navigation, search

Difference between revisions of "ASM Eave Protection and Underlayment (Low Slopes)"

 
(20 intermediate revisions by the same user not shown)
Line 1: Line 1:
<hr>
+
{{Template:RPM Info}}
[[File:8.1.4.2.1.jpg]]
 
 
 
 
 
=== WORK INCLUDED ===
 
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment and Eave Protection''']]: One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
 
;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMEDGE|'''Edge Metal Flashing''']]: Installed to manufacturer's printed instructions.
 
  
:'''Note''': This specification is applicable to slopes 1:6 (2" in 12") and greater.
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
  
 +
<big><big>Division D - Construction Details</big></big>
 
<hr>
 
<hr>
 +
<big><big><big><big><big>ASM | Eave Protection and Underlayment (Low Slopes) ([[ASM_Roof_Systems_Standard#8.3.2.1. Installation of Eave Protection | Article 8.3.2.1.]] and [[ASM_Roof_Systems_Standard#8.3.2.4. Underlayment for Slopes Less Than 1:3 | Article 8.3.2.4.]])</big></big></big></big></big>
 +
{{Template:Construction Details Header}}
  
  
=== RELATED WORK BY OTHERS ===
+
<div class="panel panel-success">
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
+
<div class="panel-heading"><big>'''ASM Details'''</big></div>
 +
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:ASM 8.1.2 Self-Adhered Underlayment.jpg|class=img-responsive | link=http://rpm.rcabc.org/images/b/bd/ASM_8.1.2_Self-Adhered_Underlayment.jpg]]
 +
</div>
  
 +
::Click below for a printable version of this page (N/A)
  
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
+
<div style="width:150px; text-align: left;">
 +
:[[File:Pdf.png|100 px|link=|'''Print Sheet''']]
 +
</div>
 +
</div><!-- COL-MD-6 -->
  
 +
<div class="col-md-6">
 +
=== WORK INCLUDED ===
 +
;(1) [[ASM Roof Systems Standard#PART_13 | '''Metal flashing underlayment/separation membrane''']]: Required for metal flashings installed on wood substrates.
 +
;(2)[[ASM Roof Systems Standard#PART_13 | '''Metal edge flashing''']]: Installed to manufacturer's printed instructions.
 +
;(3) [[ASM Roof Systems Standard#PART_8 |'''Ice and water protection''']]: One ply of accepted self-adhered modified bituminous membrane.
 +
:* This application is required only for slopes less than 1:3 (4" in 12").  For slopes 1:3 or greater, see '''Eave Protection and Underlayment'''.
 +
:* Separation layer not shown for clarity
  
 
<hr>
 
<hr>
  
 +
=== RELATED WORK BY OTHERS ===
 +
;(A) [[ASM Roof Systems Standard#PART_2|'''Acceptable deck''']]
 +
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
  
 +
'''NOTE''': See the [[ASM Roof Systems Standard | '''Standard''']] for additional requirements.
  
 +
<hr>
  
[[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Application'']]
+
[[ASM Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Roof System Details'']]
  
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
+
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}

Latest revision as of 14:55, 28 June 2022



Division D - Construction Details


ASM | Eave Protection and Underlayment (Low Slopes) ( Article 8.3.2.1. and Article 8.3.2.4.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.


ASM Details

ASM 8.1.2 Self-Adhered Underlayment.jpg

Click below for a printable version of this page (N/A)
Print Sheet

1 WORK INCLUDED

(1) Metal flashing underlayment/separation membrane
Required for metal flashings installed on wood substrates.
(2) Metal edge flashing
Installed to manufacturer's printed instructions.
(3) Ice and water protection
One ply of accepted self-adhered modified bituminous membrane.
  • This application is required only for slopes less than 1:3 (4" in 12"). For slopes 1:3 or greater, see Eave Protection and Underlayment.
  • Separation layer not shown for clarity

2 RELATED WORK BY OTHERS

(A) Acceptable deck

NOTE: See the Standard for additional requirements.


Back to ASM Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.