Difference between revisions of "Materials:(DM Henderson) Zimmerman SS1500"

Jump to: navigation, search

Difference between revisions of "Materials:(DM Henderson) Zimmerman SS1500"

 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
Manufacturer: <b>D.M. HENDERSON ROOFING LTD.</b>  
+
__NOTOC__
 +
__NONUMBEREDHEADINGS__
 +
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
  
Contact Address: See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ '''www.rcabc.org''']
+
<big><big>Division C - Accepted Materials</big></big>
 +
<hr>
 +
<big><big><big><big><big>Zimmerman SS1500</big></big></big></big></big><br>
 +
<big><big><big>by D.M. Henderson Roofing Ltd.</big></big></big><br>
 +
{| class="wikitable"
 +
|-
 +
| style="background-color: #ffffcc; column-width:100%" | The metal panel listed and described below is accepted for use in the '''''RoofStar Guarantee Program'''''.
 +
|}
 +
{| class="wikitable"
 +
|-
 +
|
 +
;'''Manufacturer''': D.M. Henderson Roofing Ltd.
 +
;'''Contact Address''': See the current Membership list and contact information at [http://www.rcabc.org/members/find-a-member/ www.rcabc.org]
 +
;'''Product Group - Standing Seam Metal Roof System'''
 +
;'''Panel Machine''': Zimmerman
 +
;'''Panel Name''': Zimmerman SS1500
 +
;'''Seam Type''': Mechanical Lock
  
Product Group: <b>STANDING SEAM METAL ROOF SYSTEM &#8211; ZIMMERMAN SS1500 STANDING SEAM PANEL</b>
+
The roofing assembly / material information published below and in the [http://{{SERVERNAME}}/index.php?title=Main_Page RCABC Roofing Practices Manual] DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.  For more information about this product or system, consult the manufacturer.
 +
|}
  
;DESCRIPTION
+
====OVERVIEW====
 +
The Zimmerman SS1500 is an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 500 mm (20") wide with a standing seam height of 38 mm (1 1/2").
  
:The Zimmerman SS1500 is an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 500 mm (20") wide with a standing seam height of 38 mm (1 1/2").  
+
This on-site manufacturing eliminates the need for end laps, with continuous panel forming capabilities in lengths up to 46 m (150'). Panel clips for longer length panels to be two piece assemblies, for thermal expansion and contraction design allowances, using 20 gauge metal conforming to 150-ST-22G and 500-SB-22-g base by AMSI or Approved equivalent.
  
:This on-site manufacturing eliminates the need for end laps, with continuous panel forming capabilities in lengths up to 46 m (150'). Panel clips for longer length panels to be two piece assemblies, for thermal expansion and contraction design allowances, using 20 gauge metal conforming to 150-ST-22G and 500-SB-22-g base by AMSI or Approved equivalent.
+
====SYSTEM DESCRIPTION====
 +
#'''General''':Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
 +
#'''Range of application''': On wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction. Plywood decking is to be a nominal 13 mm (1/2") thick or thicker.
 +
#'''Fasteners (Screws)''': Fasteners used to attach clips to plywood to be #8 x 1" long, pancake head, A-point, coated steel screw. Minimum two screws per clip. For steel decking or Z-girts the same size of screw with a pancake head, having a self-drill and tap point, and again two screws per clip.
 +
#'''Panel Clips''': One piece clip 64 mm (2 &#189;") wide by 38 mm (1 &#189;") high with a 16 mm (5/8") base. The minimum thickness is 22 gauge metal; fastened to a plywood deck 600 mm (24") O.C.  Custom-Bilt 2SS RC1.5" standing seam roof clip.
 +
#'''Deck Requirements''': in keeping with the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
  
;1.1 <u>GENERAL</u>
+
====PROFILE====
:The roofing assembly / material information published in the <b>RCABC <i>Roofing Practices Manual</i></b> DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority.
+
N/A
  
;1.2 <u>SYSTEM DESCRIPTION</u>
+
====TECHNICAL DATA SHEET====
:.1 Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
+
N/A
:.2 The range of application for this panel: on sloped wood or metal roof decks; in residential, commercial, and industrial applications; for new or reroof.
 
:.3 Panel Attachment:
 
  
::<b> Panel Clips</b> &#8211; one piece clip 64 mm (2 &#189;") wide by 38 mm (1 &#189;") high with a 16 mm (5/8") base. The minimum thickness is 22 gauge metal; fastened to a plywood deck 600 mm (24") on centre.  Custom-Bilt 2SS RC1.5" standing seam roof clip.  
+
====SITE CONDITIONS====
 +
Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").  
  
::<b> Fasteners</b> - used to attach clips to plywood to be #8 x 1" long, pancake head, A-point, coated steel screw. Minimum two screws per clip. For steel decking or Z-girts the same size of screw with a pancake head, having a self-drill and tap point, and again two screws per clip.  
+
====PERFORMANCE REQUIREMENTS====
 +
<ol>
 +
<li>'''Wind Uplift Resistance''': Panel securement shall conform to the requirements in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#PART_3 Part 3] of the [http://rpm.rcabc.org/index.php?title=Standard_for_Architectural_Sheet_Metal_(ASM)_Systems Standard for Architectural Sheet Metal (ASM) Systems].
 +
<li>'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in [https://rpm.rcabc.org/index.php?title=ASM_Roof_Systems_Standard#Section_9.2._Materials Section 9.2.] of the Standard.
 +
</li></ol>
  
:.4 Plywood decking is to be a nominal 13 mm (1/2") thick or thicker.
+
<hr>
  
;1.3 <u>SITE CONDITIONS</u>
 
:.1 Minimum roof slope is 1:6 (2" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").
 
  
;1.4 <u>PERFORMANCE REQUIREMENTS</u>
+
[[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Site-Formed Metal Roofing Systems'']]
 
 
:#'''Wind Uplift Standards''': Engineered designs to resist wind uplift may refer to the British Columbia Building Code, Div. B, Appendix C, Table C-2 which lists various types of loads, including wind loads, for specific reference locations throughout the province. See also [http://{{SERVERNAME}}/index.php?title=ASM_Application_Guides_and_Notes Guides and Notes (Wind Resistance)] for a simplified calculation procedure. Regardless of the resources indicated here, the Design Authority is responsible to perform accurate wind load calculations and specify securement requirements.
 
:#'''Materials''':RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the standards published in the [http://{{SERVERNAME}}/index.php?title=ASM_(Architectural_Sheet_Metal)_Roof_Assemblies Architectural Sheet Metal (ASM) Roof Standards].
 
 
 
<hr>
 
  
 +
[[Materials by Product Type|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']]
  
[[Architectural Metal Roofing|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Site-Formed Metal Roofing Systems'']]
 
  
 
[[Main Page|Home]]
 
[[Main Page|Home]]

Latest revision as of 17:09, 26 October 2023



Division C - Accepted Materials


Zimmerman SS1500
by D.M. Henderson Roofing Ltd.

The metal panel listed and described below is accepted for use in the RoofStar Guarantee Program.
Manufacturer
D.M. Henderson Roofing Ltd.
Contact Address
See the current Membership list and contact information at www.rcabc.org
Product Group - Standing Seam Metal Roof System
Panel Machine
Zimmerman
Panel Name
Zimmerman SS1500
Seam Type
Mechanical Lock

The roofing assembly / material information published below and in the RCABC Roofing Practices Manual DOES NOT represent a complete set of the manufacturer's published data, nor does it represent a detailed specification. The preparation of a detailed specification is the responsibility of the design authority. For more information about this product or system, consult the manufacturer.

OVERVIEW

The Zimmerman SS1500 is an on-site continuous panel metal roofing machine. Panel profiles vary from 300 mm (12") to 500 mm (20") wide with a standing seam height of 38 mm (1 1/2").

This on-site manufacturing eliminates the need for end laps, with continuous panel forming capabilities in lengths up to 46 m (150'). Panel clips for longer length panels to be two piece assemblies, for thermal expansion and contraction design allowances, using 20 gauge metal conforming to 150-ST-22G and 500-SB-22-g base by AMSI or Approved equivalent.

SYSTEM DESCRIPTION

  1. General:Standing seam panels use a hidden fastening clip system for mechanical fastening to a solid substrate. The maximum spacing of the clips is 600 mm (24") on centre. The panels are locked together, with the clips as part of the seam, by use of a mechanical seamer.
  2. Range of application: On wood or metal sloped roofs; in commercial, institutional, industrial and residential construction; for re-roofing or new construction. Plywood decking is to be a nominal 13 mm (1/2") thick or thicker.
  3. Fasteners (Screws): Fasteners used to attach clips to plywood to be #8 x 1" long, pancake head, A-point, coated steel screw. Minimum two screws per clip. For steel decking or Z-girts the same size of screw with a pancake head, having a self-drill and tap point, and again two screws per clip.
  4. Panel Clips: One piece clip 64 mm (2 ½") wide by 38 mm (1 ½") high with a 16 mm (5/8") base. The minimum thickness is 22 gauge metal; fastened to a plywood deck 600 mm (24") O.C. Custom-Bilt 2SS RC1.5" standing seam roof clip.
  5. Deck Requirements: in keeping with the Standard for Architectural Sheet Metal (ASM) Systems.

PROFILE

N/A

TECHNICAL DATA SHEET

N/A

SITE CONDITIONS

Minimum roof slope is 1:4 (3" in 12"). Severe conditions (heavy snow or ice) minimum slope is 1:1.5 (8" in 12").

PERFORMANCE REQUIREMENTS

  1. Wind Uplift Resistance: Panel securement shall conform to the requirements in Part 3 of the Standard for Architectural Sheet Metal (ASM) Systems.
  2. Materials:RoofStar (RGC) accepted metal panel systems shall be formed of steel conforming to the requirements published in Section 9.2. of the Standard.


Back to Site-Formed Metal Roofing Systems

Back to Accepted Materials


Home