Difference between revisions of "Materials:Alsan Flashing"

Jump to: navigation, search

Difference between revisions of "Materials:Alsan Flashing"

(Created page with "{| class="wikitable" |- | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': The roofing assembly / material information published in the RCA...")
 
 
(2 intermediate revisions by the same user not shown)
Line 21: Line 21:
 
:;Definition: Ready to use waterproofing, one component polyurethane / bitumen coating.
 
:;Definition: Ready to use waterproofing, one component polyurethane / bitumen coating.
  
:;Application: Upstands and roof details.
+
:;Application: Coatings for galvanized flashings (see '''''RoofStar Guarantee Standards'''''), or around details where a 2-part fleece-reinforced PMMA flashing is not required.
  
 
:;Presentation: Thixotropic paste (mixing reduces the viscosity).
 
:;Presentation: Thixotropic paste (mixing reduces the viscosity).
Line 27: Line 27:
 
:;Colour: Brown
 
:;Colour: Brown
  
:;Application: Upstand angles, support junctions and joints - accepted for use above the water plane, or as a coating on BUR vents and other strip-in flashings requiring a coating (see '''''RoofStar Guarantee Standards''''' for SBS-modified Bitumen Roof Assemblies, 12.4 Strip-in Flashings)
+
:;Application: Upstand angles, support junctions and joints - accepted for use above the water plane, or as a coating on BUR vents and other strip-in flashings requiring a coating.
  
 
:;Format: 0.15 m (6") wide x 30.5 m (100 ft) long strip.
 
:;Format: 0.15 m (6") wide x 30.5 m (100 ft) long strip.

Latest revision as of 16:14, 7 August 2019

Notice to the Reader:

The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority.

Manufacturer: Soprema Inc.
Accepted for RoofStar Guarantee Program
Date TBA
Product Summary
The Alsan Flashing is a waterproofing one-component polyurethane / bitumen coating. It is used for the upstands and roofing details where it is difficult to apply waterproofing membranes (example: complex upstands with numerous angles, hard to reach areas due to their narrowness or their environment, circular flashings, etc.).
Alsan Flashing is ready to use. It is installed directly over traditional bituminous waterproofing or approved substrates. This liquid waterproofing process applies where torches are prohibited or dangerous (example: inflammable environments, skylight flashings, etc.).
The Alsan Flashing has a 100 g/m², 150 mm (6") wide reinforcement that must be installed at all angles and joints between two supports.
ALSAN FLASHING
Definition
Ready to use waterproofing, one component polyurethane / bitumen coating.
Application
Coatings for galvanized flashings (see RoofStar Guarantee Standards), or around details where a 2-part fleece-reinforced PMMA flashing is not required.
Presentation
Thixotropic paste (mixing reduces the viscosity).
Colour
Brown
Application
Upstand angles, support junctions and joints - accepted for use above the water plane, or as a coating on BUR vents and other strip-in flashings requiring a coating.
Format
0.15 m (6") wide x 30.5 m (100 ft) long strip.
Click below for the Technical Data Sheets
Alsan Flashing - Technical Data Sheet



Back to Accepted Materials


Home