Difference between revisions of "SBS Expansion Joint (Field)"

Jump to: navigation, search

Difference between revisions of "SBS Expansion Joint (Field)"

(WORK INCLUDED)
 
(2 intermediate revisions by the same user not shown)
Line 13: Line 13:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
<div style="text-align:center; vertical-align:center">
 
<div style="text-align:center; vertical-align:center">
[[File:10.3.4.1.jpg|link=http://rpm.rcabc.org/images/7/76/10.3.4.1.jpg | class=img-responsive]]
+
[[File:Part 10 - SBS Expansion Joint (field).png|link=https://rpm.rcabc.org/images/3/3a/Part_10_-_SBS_Expansion_Joint_%28field%29.png | class=img-responsive]]
 
</div>
 
</div>
 
</div><!-- COL-MD-6 -->
 
</div><!-- COL-MD-6 -->
Line 19: Line 19:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[SBS Roof Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: If required by design authority
+
;(1) [[SBS Roof Systems Standard#PART_10|'''Base sheet membrane flashing''']]: Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with.
;(2) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
+
;(2) [[SBS Roof Systems Standard#PART_10|'''Expansion joint (elastomeric product illustrated)''']]: This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others.  Secured to substrate as required by manufacturer.
;(3) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: As required.
+
;(3) '''Reinforced membrane strip''': Applied to cover the control joint and seal it to the base membrane system.
;(4) [[SBS Roof Systems Standard#PART_9|'''Primary Membrane''']] and Membrane Protection.
+
;(4) [[SBS Roof Systems Standard#PART_10|'''Cap sheet membrane flashing''']]: Installed as required in Part 10 and applied as the second or third of a two or three-ply membrane system, providing required coverage above the finished roof system surface.  Smooth membrane is shown on parapet coping (may be granule-surfaced, depending on material specified).
;(5) [[SBS Roof Systems Standard#PART_10|'''Membrane Flashing''']]: Mechanically fasten to top of blocking (C).
+
;(5) [[SBS Roof Systems Standard#PART_13|'''Metal cap (coping) flashing''']]: Fabricated and installed as required in Part 13.
;(6) [[SBS Roof Systems Standard#PART_10|'''Membrane Underlay''']]: Minimum self-adhered modified bitumen or as per membrane manufacturer&#8217;s recommended detail.
+
;(6) [[SBS Roof Systems Standard#PART_13|'''Metal counter-flashing''']]: The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movementDimensions are project-specific.
;(7) [[SBS Roof Systems Standard#PART_13|'''Metal Counter-flashing''']]: Mechanically fasten to top of wood blocking. Optional on flexible membrane systems. Required on assemblies using gravel ballast filter matsAlso called a ''base flashing''.
+
 
;(8) [[SBS Roof Systems Standard#PART_13|'''Metal Cap Flashing''']]: Top surface must be sloping. Extend beyond and over-break at top corners. Fasten with concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams.
 
  
 
<hr>
 
<hr>
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Deck Structure''']]
+
;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable deck''']]
;(B) '''Air / Vapour Seal'''
+
;(B) '''Expansion joint structure'''
;(C) [[SBS Roof Systems Standard#PART_10|'''Expansion Joint Assembly''']]: Minimum 200 mm (8") and maximum 300 mm (12") above finished roof surface. Minimum height may be reduced to 100mm (4") if the primary roof membrane flashing is fully supported and sealed over the top.  Primed where applicable. Top must be sloped.
 
;(D) <b>Flexible Insulation</b>
 
 
</div><!-- COL-6-MD -->
 
</div><!-- COL-6-MD -->
 
</div><!-- PANEL BODY -->
 
</div><!-- PANEL BODY -->

Latest revision as of 16:29, 12 December 2022



Division D - Construction Details


SBS | Expansion Joint (Field) ( Article 10.3.6.1.)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).

The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text.

SBS Details

Part 10 - SBS Expansion Joint (field).png

1 WORK INCLUDED

(1) Base sheet membrane flashing
Waterproofs the expansion joint structure and provides a base layer for the control joint material to bond with.
(2) Expansion joint (elastomeric product illustrated)
This joint is proprietary to its manufacturer and will be fitted, manufactured, and installed (or its installation supervised) by others. Secured to substrate as required by manufacturer.
(3) Reinforced membrane strip
Applied to cover the control joint and seal it to the base membrane system.
(4) Cap sheet membrane flashing
Installed as required in Part 10 and applied as the second or third of a two or three-ply membrane system, providing required coverage above the finished roof system surface. Smooth membrane is shown on parapet coping (may be granule-surfaced, depending on material specified).
(5) Metal cap (coping) flashing
Fabricated and installed as required in Part 13.
(6) Metal counter-flashing
The counter-flashing below the cap flashing is secured independently of the metal cap flashing to permit movement of the expansion joint assembly across the planes of anticipated structural movement. Dimensions are project-specific.



2 RELATED WORK BY OTHERS

(A) Acceptable deck
(B) Expansion joint structure

NOTE: See the Standard for additional requirements.


Back to "SBS" Roof System Details

Home

© RCABC 2024
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.