− | + | === WORK INCLUDED === | |
(1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications. | (1) <b>Membrane Primer or Adhesive: </b>proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications. | ||
Line 12: | Line 12: | ||
− | + | === WORK BY OTHERS === | |
(A) <b>Acceptable Deck</b>: Concrete slab shown | (A) <b>Acceptable Deck</b>: Concrete slab shown |
Revision as of 22:44, 23 December 2015
1 WORK INCLUDED
(1) Membrane Primer or Adhesive: proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
(2) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.
(3) Protection Board & Filter Fabric: Proprietary (purpose-made) drainage boards and filter fabric required with semi- impermeable sand and gravel beds designed to provide levelling for unit masonry.
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab shown
(B) Drain Body: Proprietary Bi-level cast iron roof for waterproofing assembly with low previous wearing courses.
(C) Drain inlet: Drainage opening at top surface of semi- impermeable wearing courses on Bi-Level drain. (D) Drainage Board /Filter Fabric: Proprietary drainage board approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.
(E) Sand/ Gravel Bed with Filter Mat: synthetic water permeable fabric required to contain sand beds for unit masonry (bricks, pavers and stone).
(F) Unit Masonry Wearing Course: Concrete brick, pavers and stone on sand or gravel beds designed to support predicted live loads.
NOTE: * Refer to RGC Guarantee Standards for additional requirements.