Difference between revisions of "Materials:Elevate ISOGARD CG"
Difference between revisions of "Materials:Elevate ISOGARD CG"
(Created page with "{| class="wikitable" |- | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': The roofing assembly / material information published in the RCA...") |
|||
Line 11: | Line 11: | ||
;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ||
;: | ;: | ||
− | ;'''Product Summary''': | + | ;'''Product Summary''': Firestone '''RESISTA''' roof insulation consists of a closed-cell polyisocyanurate foam core laminated to a specially coated, inorganic, fibreglass facer. It provides outstanding fire, wind and thermal performance for commercial roofing applications. It can be used with all Firestone Roofing Systems Membrane. |
− | Firestone '''RESISTA''' roof insulation consists of a closed-cell polyisocyanurate foam core laminated to a specially coated, inorganic, fibreglass facer. It provides outstanding fire, wind and thermal performance for commercial roofing applications. It can be used with all Firestone Roofing Systems Membrane. | + | |
+ | :<u>FIRESTONE RESISTA</u> | ||
+ | |||
+ | :Firestone RESISTA roof insulation consists of a closed-cell polyisocyanurate foam core laminated to a specially coated, inorganic, fibreglass facer. It provides outstanding fire, wind and thermal performance for commercial roofing applications. It can be used with all Firestone Roofing Systems Membrane. | ||
+ | |||
+ | |||
+ | :<table border=0 cellpadding=10 cellspacing=0> | ||
+ | <tr> | ||
+ | <td>Long Term Thermal Resistance (LTTR):</td> | ||
+ | <td colspan=2>RSI value = 1.06 / 25 mm (1") [R Value = 6.0 / 25mm (1")]</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Standards</td> | ||
+ | <td colspan=2>Factory Mutual (FM) approved for Class I insulated steel deck construction (tested to FM 4450 standard)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Foamed plastic for built-up roof covering classified by Underwriters Laboratories of Canada (ULC) as to an external fire exposure only (per ULC S107)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Foamed plastic classified by Underwriters Laboratories of Canada as roof deck construction material with resistance to internal fire exposure for use in Construction No. C8 (tested to CAN / ULC-S126M)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Foamed plastic classified by Underwriters Laboratories of Canada for Fire Resistance Classification (tested to CAN / ULC-S101-M89). See ULC List of Equipment and Material Directory (Vol. III).</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Based on current UL, ULC and / or FM test data, Firestone Resista complies with the following model building codes when installed in accordance with UL, ULC and / or FM requirements: BOCA, ICBO, SBCCI, Metro-Dade 92-0930.02 and CAN/ULC- S704-01/ CAN / CGSB 51.26-M86. </td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Resista is mold resistant as per ASTM D3273 standards.</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Standard Sizes</td> | ||
+ | <td>1.2 m x 1.2 m<br>(4' x 4')</td> | ||
+ | <td>1.2 m x 2.4 m<br>(4' x 8')</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td></td> | ||
+ | <td colspan=2>Thicknesses: 25.4 mm to 101.6 mm (1" to 4")</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
<u>FIRESTONE RESISTA TAPERED ROOF INSULATIONS</u> | <u>FIRESTONE RESISTA TAPERED ROOF INSULATIONS</u> |
Revision as of 21:30, 3 November 2016
Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Firestone Building Products
|
- Click below for the Technical Data Sheet (TBA).