Materials by Product Category
Materials by Product Category
Division C - Accepted Materials
Materials by Product Category
ACCEPTED MATERIALS and SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.
Many material pages are missing acceptance dates; this is a carry-over from a prior iteration of the RPM, in which those dates were not recorded. If the date is missing, it is usually shown with the acronym "TBD" (To Be Determined). You may also search for RoofStar Accepted Materials by Finally, note that those RoofStar Accepted Materials which have been tested for wind uplift resistance can be found through links on the Main Page of the RPM. |
NOTE: Primers, cleaners, sealants, mastics, adhesives, fasteners, and all other similar products necessary to construct a roof system, are not expressly accepted by the RGC and therefore are not listed in this Manual. However, they must be proprietary to, or acceptable for use by, the manufacturer of the primary material. Where Tested Assemblies are concerned, the precise products listed in the test report must be used, unless expressly permitted by the manufacturer. |
Primary Materials:
Membranes
1 SBS Polymer-Modified Bituminous Membranes
2 APP Polymer-Modified Bituminous Membranes
3 EPDM Membranes
Primary Materials:
Membranes Cont.
4 TPO Membranes
5 PVC Membranes
6 Fluid-applied Membranes
7 BUR Systems
Primary Materials:
Other
8 Liquid Membrane Flashing Systems
9 Drains and Penetration Flashings
Secondary Materials:
Insulation & Overlays
ACCEPTED MATERIALS and SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.
Many material pages are missing acceptance dates; this is a carry-over from a prior iteration of the RPM, in which those dates were not recorded. If the date is missing, it is usually shown with the acronym "TBD" (To Be Determined). You may also search for RoofStar Accepted Materials by Finally, note that those RoofStar Accepted Materials which have been tested for wind uplift resistance can be found through links on the Main Page of the RPM. |
NOTE: Primers, cleaners, sealants, mastics, adhesives, fasteners, and all other similar products necessary to construct a roof system, are not expressly accepted by the RGC and therefore are not listed in this Manual. However, they must be proprietary to, or acceptable for use by, the manufacturer of the primary material. Where Tested Assemblies are concerned, the precise products listed in the test report must be used, unless expressly permitted by the manufacturer. |
Primary Materials:
Membranes
1 SBS Polymer-Modified Bituminous Membranes
2 PVC Membranes
Primary Materials:
Membranes Cont.
3 Butyl Membranes
4 Fluid-applied Membranes
Primary Materials:
Other
5 Liquid Membrane Flashing Systems
6 Drains and Penetration Flashings
ACCEPTED MATERIALS and SYTEMS for a RoofStar 5-year Guarantee, RoofStar 10-year Guarantee, or for a RoofStar 15-year Guarantee.
Many material pages are missing acceptance dates; this is a carry-over from a prior iteration of the RPM, in which those dates were not recorded. If the date is missing, it is usually shown with the acronym "TBD" (To Be Determined). You may also search for RoofStar Accepted Materials by Finally, note that those RoofStar Accepted Materials which have been tested for wind uplift resistance can be found through links on the Main Page of the RPM. |
NOTE: Primers, cleaners, sealants, mastics, adhesives, fasteners, and all other similar products necessary to construct a roof system, are not expressly accepted by the RGC and therefore are not listed in this Manual. However, they must be proprietary to, or acceptable for use by, the manufacturer of the primary material. Where Tested Assemblies are concerned, the precise products listed in the test report must be used, unless expressly permitted by the manufacturer. |
Primary Materials:
Asphalt Shingles/ASM
Primary Materials:
Other
1 Cedar Shingles & Shakes/Tiles/Slate
2 Drains and Penetration Flashings
Secondary Materials:
Underlayment/Eaves
3 Asphalt Shingle and Cedar Systems
4 Architectural Sheet Metal (ASM) Systems
Secondary Materials:
Insulation & Overlays
ACCEPTED SYTEMS for a RoofStar Vegetated Roof Guarantee.
You may also search for RoofStar Accepted Materials by Finally, note that those RoofStar Accepted Materials which have been tested for wind uplift resistance can be found through links on the Main Page of the RPM. |
NOTE: Only the major components necessary to construct a vegetated roof system are listed on the pages for the systems shown in this table; minor components (i.e., connecting plates for edge metal) are not shown. For a complete list of required and optional accessories or components, contact the local representative for the system manufacturer. |
VRS Supplier | VR System Name * | VRS Type † | System Min. Depth mm (in) ‡ |
System Max. Depth mm (in) |
Media Min. Depth mm (in) ‡ |
Media Max. Depth mm (in) |
---|---|---|---|---|---|---|
Carlisle SynTec Systems Canada | Carlisle Extensive Roof Garden System | Extensive | 101.6 (4) | 127 (5) | 70 (1-1/4) | 127 (5) |
Carlisle SynTec Systems Canada | Carlisle Roof Garden Extensive Stormwater Retention System | Extensive | 140 (5-1/2) | 140 (5-1/2) | 101.6 (4) | 101.6 (4) |
Carlisle SynTec Systems Canada | Carlisle Semi-Intensive Roof Garden System | Semi-intensive | 158.8 (6-1/4) | 235 (9-1/4) | 127 (5) | 203.2 (8) |
Carlisle SynTec Systems Canada | Carlisle Intensive Roof Garden System | Intensive | 235 (9-1/4) | None Stated | 203.2 (8) | None Stated |
Hydrotech Membrane Corporation | Hydrotech Extensive Garden Roof Assembly | Extensive | 101.6 (4) | 203.2 (7) | 76.2 (3) | 152.4 (6) |
Hydrotech Membrane Corporation | Hydrotech Semi-intensive Garden Roof Assembly | Semi-intensive | 203.2 (8) | 355.6 (14) | 152.4 (6) | 304.8 (12) |
Hydrotech Membrane Corporation | Hydrotech Intensive Garden Roof Assembly | Intensive | 355.6 (14) | 939.8 (37) | 304.8 (12) | 889 (35) |
Next Level Stormwater Management | NLSM LiteN'Less | Extensive | 40.7 (1-5/8) | 64.0 (2-1/2) | 25.4 (1) | 25.4 (1) |
Next Level Stormwater Management | NLSM LiteN'Less II | Extensive | 30.7 (1-1/8) | 30.7 (1-1/8) | 20 (13/16) | 20 (13/16) |
Next Level Stormwater Management | NLSM LiteN'Less III | Extensive | 45.0 (1-13/16) | 62.0 (2-7/16) | 20 (13/16) | 20 (13/16) |
Next Level Stormwater Management | NLSM TerraEXT | Extensive | 113.0 (4-13/16) | 188 (7-13/16) | 95.0 (3-3/4) | 170 (6-11/16) |
Next Level Stormwater Management | NLSM StormCap | Extensive | 114 (4-1/2) | 264 (10-3/8) | 70 (2-3/4) | 170 (6-11/16) |
Next Level Stormwater Management | NLSM StormCap Detain 3° | Extensive | 114 (4-1/2) | 352 (13-7/8) | 70 (2-3/4) | 170 (6-11/16) |
Next Level Stormwater Management | NLSM Eco-Grass | Semi-intensive | 188 (7-7/16) | 338 (13-5/16) | 170 (6-11/16) | 320 (12-9/16) |
Next Level Stormwater Management | NLSM Flora Garden | Intensive | 162 (6-3/8) | 312 (12-5/16) | 150.4 (6) | 304.8 (12) |
Soprema Inc. | SOPRANATURE® Extensive-Conv. Veg. Roof | Extensive | 85.85 (3-3/8) | 162 (6-3/8) | 76.2 (3) | 152.4 (6) |
Soprema Inc. | SOPRANATURE® Extensive-Inverted Veg. Roof | Extensive | 88.1 (3-6/16) | 164.3 (6-6/16) | 76.3 (3) | 152.4 (6) |
Soprema Inc. | SOPRANATURE® Modular-Conv. Veg. Roof | Extensive | 100.5 (3-15/16) | 100.5 (3-15/16) | 100 (3-7/8) | 100 (3-7/8) |
Soprema Inc. | SOPRANATURE® Modular-Inverted Veg. Roof | Extensive | 100.5 (3-15/16) | 100.5 (3-15/16) | 100 (3-7/8) | 100 (3-7/8) |
Soprema Inc. | SOPRANATURE® Semi-Intensive-Inverted Veg. Roof | Semi-intensive | 164.3 (6-6/16) | 316.7 (12-6/16) | 152.4 (6) | 304.8 (12) |
Soprema Inc. | SOPRANATURE® Intensive-Inverted Veg. Roof | Intensive | 361.7 (12-6/16) | 361.7 (12-6/16) + | 304.8 (12) | 304.8 (12) + |
Soprema Inc. | SKYWATER® Ballasted-Inverted Hybrid Roof | Hybrid† | 107.9 (4-1/4) | 336.5 (13-1/4) + | 76.3 (3) | 304.8 (12) + |
Soprema Inc. | SKYWATER® SOPRAFLOW CONTROL | Hybrid† | 136.9 (5-3/8) | 265.2 (14-3/8) | 76.3 (3) | 304.8 (12) + |
- * Click on the Vegetated Roof Name to link to the system page for specified or optional vegetation profiles
- † Vegetated roof systems can be divided into three classic types: Extensive, Semi-intensive, and Intensive. Added to this are blue-green roofs, also referred to as "hybrid systems." Refer to the Notes to the Notes to the Standard for Vegetated Roofs for an expanded treatment on the three principal types. To learn more about RGC requirements for hybrid systems, see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
- ‡ Minimum system and growing media depths may vary. For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements. This may affect the minimum thickness of a system. Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture). Always refer to the system page for more information.
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.