− | ;'''Product Summary''': | + | ;'''Product Summary''': Polyisocyanurate '''H-Shield Composite''' is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield Composite''' insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate '''H-Shield Composite''' is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR). |
− | Polyisocyanurate '''H-Shield Composite''' is a foam core insulation board covered on both sides with a medium weight fiber-glass reinforced facer. This dimensionally stable, durable insulation offers maximum thermal efficiency. Hunter Panels Polyisocyanurate '''H-Shield Composite''' insulation is UL and FM approved as a system component in certain roofing assemblies. Polyisocyanurate '''H-Shield Composite''' is also available in tapered form. The industry follows CAN / ULC-S770 test method for determining a 15-year time-weighted average Long Term Thermal Resistance (LTTR). | + | |
+ | :<u>TYPICAL PROPERTIES AND CHARACTERISTICS:</u> | ||
+ | |||
+ | :<table border=0 cellpadding=5 cellspacing=0> | ||
+ | <tr> | ||
+ | <td>Nominal Thickness inches (mm)</td><td>• 1.0 (25)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>LTTR R-Value*</td><td>• 6.0</tD> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>LTTR C-Value*</td><td>• 0.167</tD> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>T-Load Quantity Sq. Ft. (Sq. M.)</td><td>• 32,384 (3,009)</tD> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Flute Span Ability, in. (mm)</td><td>• 2-5/8 (67)</tD> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Minimum Thickness, in (mm)</td><td>• 0.95 (24)</tD> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <u>PHYSICAL PROPERTIES:</u> | ||
+ | <table border=0 cellpadding=5 cellspacing=0> | ||
+ | <tr> | ||
+ | <td><u>Property</u></td><td><u>Test Method</u></td><td><u>Specification Limits</u></td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Compressive Strength, psi (kPa)</td><td>ASTM D1621 Procedure A</td><td>Minimum 20 (138)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Moisture Vapour Transmission, perms</td><td>ASTM C355</td><td>Maximum 1.0</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Foam core Density, lb / ft<sup>3</sup> (kg / m<sup>3</sup>)</td><td>ASTM D1622</td><td>Nominal 2.0 (32)</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Flame Spread (foam core)</td><td>ASTM E84</td><td>Maximum 25</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>Service Temperature, range if ºF (ºC)</td><td>- - -</td><td>-100 (-73) to 250 (121)</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | Hunter Panels Polyisocyanurate H-Shield Composite meets or exceeds ASTM C1289 (Type II, Class 1, Grade 2) and Federal Specification HH-I-1972/2. | ||
+ | |||
|} | |} | ||