Difference between revisions of "Materials:Retrofit Board"
Difference between revisions of "Materials:Retrofit Board"
(Created page with "<i>Manufacturer:</i> <b>JOHNS MANVILLE CORPORATION</b> <i>Contact Address:</i> See Membership List, Section 1 <i>Product Group:</i> <b>PERLITIC ROOF INSULATION - RETRO-FIT B...") |
|||
(7 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | {| class="wikitable" | |
+ | |- | ||
+ | | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': | ||
− | + | The roofing assembly / material information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. | |
+ | |} | ||
+ | {| class="wikitable" | ||
+ | |- | ||
+ | | '''Manufacturer''': [http://www.jm.com/ '''Johns Manville Corporation'''] | ||
+ | ;: | ||
+ | ;Accepted for '''''RoofStar Guarantee Program''''': Date TBA | ||
+ | ;: | ||
+ | ;'''Product Summary''': Retro-Fit Board is a perlite-based utility board for use as a divorcing layer in reroofing and in new construction as a top layer in a multi-layer insulation system. | ||
− | + | :Half-inch Retro-Fit Board is a high density board made of expanded perlite and cellulosic fibres. It serves as an upgrade for wood fibre utility roofing products. The perlite particles are subjected to intense heat, which causes them to expand approximately fifteen times their original size. | |
− | + | :The top surface is sealed with Top-Loc coating to ensure good attachment in bituminous applications. The minimum recycled content is 35% by weight. | |
− | + | :Retro-Fit Board Insulation / Overlay | |
− | + | :<table border=0 cellpadding=10 cellspacing=0> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | <table border=0 cellpadding=10 cellspacing=0> | ||
<tr> | <tr> | ||
<td>Thermal Resistance:</td> | <td>Thermal Resistance:</td> | ||
Line 58: | Line 56: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |} | ||
+ | |||
+ | :Click below for the '''Technical Data Sheet'''. | ||
+ | |||
+ | <div style="width:150px; text-align: left;"> | ||
+ | :[[File:Pdf.png|150 px|link=http://rpm.rcabc.org/images/0/03/JM_Retro-Fit_Board_TDS.pdf|'''Technical Data Sheet''']] | ||
+ | </div> | ||
+ | |||
+ | |||
+ | <hr> | ||
+ | |||
+ | [[Materials by Product Type|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']] | ||
+ | |||
+ | |||
+ | [[Main Page|Home]] |
Latest revision as of 22:01, 3 November 2016
Notice to the Reader:
The roofing assembly / material information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications. The preparation of a detailed specification is the responsibility of the design authority. |
Manufacturer: Johns Manville Corporation
|
- Click below for the Technical Data Sheet.